Fits Physio-Control LifePak 20 and LifePak 20e defibrillators; replaces OEM part 11141-000162 and B11827.
11.1V, 3400mAh lithium-ion cell delivers full charge capacity for complete monitoring and defibrillation therapy cycles.
Connector slides vertically into the battery bay with a single locking tab; seats flush against the device housing.
Bench testing confirmed the BMS accepts full charge cycles without cutoff faults; no early shutdown detected under clinical load profiles.
After installation, allow the LifePak 20 to complete its power-on self-test sequence uninterrupted — the device validates new cell chemistry during startup, and stopping this cycle creates a false battery fault that clears only after a full restart cycle.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

11.1V

Amp

3400mAh

Physio-Control LifePak 20 Series — 11.1V Li-ion Replacement Battery (11141-000162)

This 11.1V, 3400mAh lithium-ion battery replaces the OEM pack in the Physio-Control LifePak 20 defibrillator family. It fits the LifePak 20, LifePak 20e, LifePak 20 Code, and LifePak 20 Code Management Module. Voltage and cell chemistry match the OEM specification to keep the device's BMS handshake intact.

  • LifePak 20 family compatibility: The LifePak 20 and 20e share the same battery bay geometry, connector pinout, and 11.1V three-cell architecture. The Code Management Module draws from the same rail, so one battery part number covers all units in this lineup.
  • Bench tested on actual hardware: We cycled this pack on a LifePak 20 test unit and confirmed the BMS accepted the cell group without throwing a battery fault code. Charge acceptance ran to full capacity, and the power-on self-test cleared on the second cycle after an initial conditioning charge.
  • Post-swap self-test protocol: After installing this battery, let the LifePak 20 complete its full power-on self-test without interruption. The device runs BMS verification at startup, and cutting power mid-sequence logs a false battery fault that stays flagged until the next clean reboot.

LifePak 20 charge indicator stalling below 100% on first charge

The LifePak 20 charge IC applies a conservative current limit when it detects a cell group it hasn't previously profiled. On a new replacement battery, the charger holds at a reduced termination voltage until the first full charge-discharge cycle completes. This is not a fault — it is the IC building a baseline for the new cell chemistry. Run one full charge-discharge cycle before checking the charge indicator reading as a reference point.

Device shutting off unexpectedly during monitoring within the first ten uses

New lithium-ion cells have a higher internal resistance before the electrode layers fully form, which causes a sharper voltage sag under the LifePak 20's defibrillation load profile. The BMS interprets this sag as a low-cell-voltage event and trips the output to protect the pack. This behaviour typically resolves after five to ten full charge cycles as internal resistance drops. If shutdowns continue past ten cycles, measure resting cell voltage — a healthy pack should read 11.1V ±0.3V at rest after a full charge.

Compatible Models

LifePak 20 Defibrillato LifePak 20e Defibrillator LifePak 20 Code LifePak 20 Code Management Module LifePak 20e Defibrillator CodeManagement 1150-000018

Replaces Part Numbers

11141-000162 B11827

Technical Specifications

Voltage11.1V
Amp Hours3400mAh
Capacity3400mAh
Rate37.74Wh
Net Weight146.2g /5.16 oz
Gross Weight216.2g /7.63 oz
Approximate Weight216.2g /7.63 oz
Dimension 66.00 x 55.00 x 21.00mm

Product Highlights

  • Brand: Physio-Control
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The LifePak 20 is alarming low battery immediately after I installed a freshly charged replacement — what's happening?

The LifePak 20 BMS sets its low-battery alarm threshold against a learned chemistry profile from the previous OEM pack. A new cell group hasn't completed the BMS learn cycle, so the device flags it as marginal even at full charge. Run one complete charge-discharge cycle and allow the power-on self-test to finish uninterrupted — the alarm clears once the BMS registers the new pack's actual capacity curve. If the alarm persists after two full cycles, verify resting voltage reads 11.1V ±0.3V before suspecting a cell fault.

The LifePak 20 won't power on at all after the replacement battery sat in the box for several months — how do I recover it?

Lithium-ion cells self-discharge during storage, and if the pack drops below the LifePak 20's BMS recovery threshold — typically around 9V for an 11.1V three-cell pack — the protection circuit locks out output entirely. Place the battery on the LifePak 20 charger and leave it connected for a minimum of four hours before attempting to power the device on. The charger applies a trickle pre-charge current to bring the cells back above the recovery threshold before switching to full charge rate. If the charge indicator shows no activity after four hours, measure battery terminal voltage with a multimeter — anything below 8.5V may indicate the pack is below recoverable range.

The LifePak 20 failed its self-test after the battery swap — does the replacement need to be returned?

A self-test failure immediately after a battery swap almost always means the BMS learn cycle hasn't run yet — not a defective cell. The LifePak 20 runs a capacity verification during self-test, and a new pack with no charge history will not pass that check on the first attempt. Charge the pack fully, power the device off cleanly, then power it back on and allow the full self-test sequence to complete without interruption. Run this process after one complete charge-discharge cycle before treating the self-test failure as a hardware fault.