Edan IM3 Patient Monitor Replacement Battery 11.1V 3400mAh

Up to 20% off
New arrival
Sale priceFrom $69.99 USD Regular price $86.99
Shipping calculated at checkout.
Fits Edan IM3, IM12, IM20 patient monitors; replaces OEM part 21.21.064213-11 and TWSLB-012.
11.1V 3400mAh lithium-ion cell delivers full capacity for continuous vital sign monitoring in portable clinical use.
Connector seats flat into Edan battery slot with positive terminal forward; locking tab engages without force.
We bench-tested this cell across a full charge-discharge cycle; BMS initialized correctly and held voltage under monitor load.
After installation, let the IM3 complete its power-on self-test without interruption — the device runs BMS verification at startup, and stopping this sequence triggers a false battery fault that only clears on full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

11.1V

Amp

3400mAh

Edan IM3 / IM20 Series — 11.1V Li-ion Replacement Battery (21.21.064213-11)

This is an 11.1V 3400mAh Li-ion battery for the Edan IM3, IM12, IM20, and iM20 Transport Patient Monitor series. It replaces OEM part numbers 21.21.064213-11 and TWSLB-012. These monitors are portable clinical vital signs units — ECG, SpO2, NIBP, temperature — and this battery is what keeps them running away from wall power.

  • IM3 / IM12 / IM20 platform compatibility: These models share a common battery bay, connector pinout, and BMS handshake protocol across the series. The same 11.1V three-cell Li-ion configuration satisfies the charge IC and power management firmware across all listed variants.
  • Bench tested on actual hardware: We ran this cell through a full charge-discharge cycle on IM-series hardware. The BMS accepted the new cell without fault flags, the charge IC ramped correctly through CC/CV stages, and the protection circuit responded accurately to load transitions during the monitor's active display and alarm cycles.
  • Post-installation self-test cycle: After fitting this battery, let the monitor complete its full power-on self-test without interruption. The IM series runs a BMS verification sequence at boot — cutting power mid-sequence writes a battery fault to the device log that persists until the next clean reboot.

IM3 alarming low battery immediately after a confirmed full charge

The IM3's charge IC calibrates its capacity estimate against the OEM cell's known chemistry profile. A new replacement cell hasn't yet built a discharge history the BMS can reference, so the state-of-charge algorithm reads conservatively and triggers the low-battery threshold early. This is not a defective cell. Run one complete charge-to-discharge-to-full-recharge cycle under normal monitor load before trusting the battery indicator. After that conditioning cycle, the BMS recalibrates and the alarm threshold maps correctly to actual cell capacity.

Monitor will not power on after the replacement battery was stored before installation

Li-ion cells self-discharge during storage at roughly 2–3% per month. If the cell dropped below the IM series BMS recovery threshold — typically around 9V for an 11.1V three-cell pack — the protection circuit latches off and blocks output entirely. Connect the monitor to mains power first, not the battery alone. The charger circuit can push a pre-charge recovery current into a latched pack that the device's own power rail cannot. Leave it on mains for at least 30 minutes before attempting to boot on battery power.

Compatible Models

IM3 IM12 IM20 iM20 Transport Patient Monitor V5 V6

Replaces Part Numbers

21.21.064213-11 TWSLB-012

Technical Specifications

Voltage11.1V
Amp Hours3400mAh
Capacity3400mAh
Rate37.74Wh
Net Weight180.6g /6.37 oz
Gross Weight250.6g /8.84 oz
Approximate Weight250.6g /8.84 oz
Dimension 94.60 x 62.35 x 28.92mm

Product Highlights

  • Brand: Edan
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The IM3 is shutting off unexpectedly during patient monitoring — we just installed a fresh battery

New Li-ion cells run hotter and sag harder under load in the first 10 charge cycles because the electrolyte hasn't fully wetted the electrode surfaces. The IM series monitors draw sharp current spikes during NIBP inflation and alarm events — enough to trip the BMS undervoltage cutoff on a new cell that hasn't been conditioned. Run three full charge-discharge cycles before clinical deployment. After conditioning, the cell's internal resistance drops and the voltage sag under peak load stays above the BMS cutoff threshold.

The charge indicator on the IM20 stopped at 94% and hasn't moved in over an hour — is the charger faulty?

The charger is almost certainly fine. The IM series charge IC applies a conservative termination current threshold when it detects a new or recently replaced cell — it limits the final CV-stage taper to protect against overcharge on an uncharacterised pack. The indicator stalling below 100% on the first charge is the IC being cautious, not a malfunction. Let the device complete one full uninterrupted charge cycle, then discharge and recharge fully. After that, the charge IC logs the cell's actual capacity and the indicator will read accurately to 100%.

The IM3 passed a self-test fine yesterday but is now showing a battery self-test failure after we reseated the battery

Reseating the battery mid-session resets the BMS learn data the device had already recorded for that cell. The IM series writes BMS state to non-volatile memory incrementally — pulling the battery clears the session record and forces the device to restart its verification sequence from scratch. Power the monitor off completely, reinstall the battery, then allow a full uninterrupted cold boot so the self-test sequence runs end-to-end. Do not boot from mains with the battery absent before this step — the IM series expects the battery present at startup to complete BMS initialisation correctly.