Scilogex Levo PLUS 3.7V Compatible Battery 293032
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Scilogex Levo PLUS 3.7V Compatible Battery 293032 - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Scilogex Levo PLUS 3.7V Compatible Battery 293032 - is backordered and will ship as soon as it is back in stock.
Voltage
3.7V
Amp
1000mAh
Scilogex Levo PLUS — 3.7V Li-ion Replacement Battery (293032)
This 3.7V 1000mAh Li-ion cell restores cordless operation to the Scilogex Levo PLUS and Levo Plus Motorized Pipette Filler. It replaces OEM part numbers 293032, 293032-A, 293032-B, and 293032-C. The Levo PLUS is a portable laboratory mixer used for vortex and orbital sample preparation in medical and clinical settings.
- Levo PLUS and Motorized Pipette Filler compatibility: Both devices share the same 3.7V cell format, connector pinout, and BMS handshake. The OEM suffix variants (A, B, C) reflect production revisions only — the cell specification is unchanged across all variants.
- Bench tested on actual hardware: We ran this cell through charge and discharge cycles on the Levo PLUS platform. The BMS completed its current monitoring and cutoff checks without triggering any fault flags across multiple cycles.
- Post-installation self-test protocol: After fitting this battery, allow the Levo PLUS to complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup — cutting power mid-sequence can latch a false battery fault that persists until a clean reboot.
Levo PLUS shutting off unexpectedly during sample mixing cycles
New Li-ion cells carry higher internal resistance in the first 5–10 cycles. The Levo PLUS load profile during active mixing draws short, repetitive bursts that stress a new cell harder than steady-state use. The BMS reads this as a voltage sag event and triggers a protective shutdown before the cell is actually depleted. Running two or three full charge-discharge cycles before clinical use brings internal resistance down and stops nuisance cutoffs.
Charge indicator not reaching 100% on first charge after battery swap
The Levo PLUS charge IC applies a conservative current limit when it detects a cell it hasn't profiled before. On the first charge, the controller may terminate early — typically between 85–95% — rather than pushing to full capacity. This is a one-time calibration behaviour, not a cell fault. Complete a full discharge down to the low-battery cutoff, then recharge uninterrupted to let the charge IC lock in the correct termination voltage for this cell.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Scilogex
- Manufacturer: CS
- Series: Standard
- Color: Blue
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The Levo PLUS is alarming low battery immediately after I put in a fully charged replacement — what's happening?
The BMS on the Levo PLUS compares the incoming cell voltage against a threshold calibrated for the OEM cell chemistry. A new replacement cell that hasn't been cycled yet can present a voltage profile the BMS reads as marginal, triggering the low-battery alarm even at full charge. This is a first-cycle calibration issue, not a faulty battery. Run one complete charge-discharge cycle on the device and the BMS will re-establish its threshold against the actual cell — the alarm clears after that cycle.
The Levo PLUS won't power on after the new battery sat unused for several weeks before installation — how do I recover it?
Li-ion cells self-discharge during storage, and if the cell voltage drops below approximately 3.0V the Levo PLUS BMS will refuse to power on as a protection measure. Place the battery in the device, connect the charger, and leave it on charge for at least 60 minutes before attempting to power on — most chargers apply a trickle recovery current that brings the cell back above the BMS acceptance threshold. If the charge indicator shows no activity after 30 minutes, check that the charger output is live and the contacts are seated correctly.
The Levo PLUS failed its power-on self-test after I swapped the battery — the fault clears if I remove and refit the cell, but comes back on the next boot. What causes this?
The self-test runs a BMS learn cycle at startup, and if a previous power-on was interrupted mid-sequence — even briefly — the device stores an incomplete test result that repeats on subsequent boots. The fix is a full reboot: remove the battery, hold the power button for 10 seconds to drain residual charge from the board, refit the battery, and allow the device to complete the entire boot and self-test sequence without touching any controls. One uninterrupted cycle clears the stored fault state.