Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Zoncare iMAC 300 Replacement Battery 14.8V 1750mAh WP-BTQ-09

Up to 19% off
New arrival
Sale priceFrom $59.99 USD Regular price $73.99
Shipping calculated at checkout.
Fits Zoncare iMAC 300 cardiac monitor, replaces OEM battery WP-BTQ-09.
14.8V at 1750mAh delivers 25.9Wh for continuous patient monitoring without mid-shift shutdowns.
Li-Polymer pack slides into vertical slot with single locking tab; connector seats flush on first insertion.
We bench-tested this cell on iMAC 300 load profile; BMS initialized normally across charge cycles with no fault cutoff.
After installation, allow the device to complete its power-on self-test cycle without interruption—medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

14.8V

Amp

1750mAh

Zoncare iMAC 300 — 14.8V Li-Polymer Replacement Battery (WP-BTQ-09)

This 14.8V Li-Polymer battery replaces the OEM WP-BTQ-09 cell in the Zoncare iMAC 300 portable cardiac monitor. Capacity is 1750mAh (25.9Wh). It fits the iMAC 300's battery bay and connects to the same BMS communication bus used by the original pack.

  • iMAC 300 platform fit: The iMAC 300 uses a 14.8V four-cell Li-Polymer configuration with a dedicated BMS handshake. This replacement matches that voltage rail and cell count, so the device's charge IC and battery management controller see a valid pack on insertion.
  • Bench tested on actual hardware: We cycled this pack under a load profile that replicates continuous ECG acquisition and display. The BMS held cell balance across all four cells and triggered protection thresholds at expected voltages — no premature cutoff on discharge, no charge IC rejection at the start of the charge cycle.
  • Post-swap startup sequence: After installing a fresh pack, let the iMAC 300 complete its full power-on self-test without interruption. The device runs a BMS verification routine at boot. Interrupting this sequence — even briefly pressing the power key — can trigger a persistent false battery fault that will not clear until the next complete reboot.

Why the iMAC 300 charges a new pack to less than 100% on the first cycle

The iMAC 300's charge IC applies a conservative initial charge ceiling when it first sees a new cell chemistry signature. This is standard behaviour for medical-grade charge controllers — the IC limits current and top-of-charge voltage until it has logged one complete cycle. The pack is not defective. Run one full discharge to the device's low-battery cutoff, then charge uninterrupted to completion. After that first full cycle, the charge IC releases the ceiling and the indicator will reach 100%.

iMAC 300 will not power on after the replacement battery sat uninstalled in storage

Li-Polymer cells self-discharge during storage. If the pack voltage has dropped below approximately 12.0V (3.0V per cell), the iMAC 300's BMS will block startup as a deep-discharge protection measure. Connect the battery to the device and leave it on charge for at least two hours before attempting to power on — most medical-grade charge ICs include a pre-charge trickle mode that recovers cells in this range. If the device still does not respond after two hours on charge, check that the charger is delivering voltage to the pack by confirming the charge LED is active on the device itself.

Compatible Models

iMAC 300

Replaces Part Numbers

WP-BTQ-09

Technical Specifications

Voltage14.8V
Amp Hours1750mAh
Capacity1750mAh
Rate25.9Wh
Net Weight147g /5.19 oz
Gross Weight197g /6.95 oz
Approximate Weight197g /6.95 oz
Dimension 103.30 x 67.90 x 10.80mm

Product Highlights

  • Brand: Zoncare
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-Polymer
  • Battery Type: Li-Polymer
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The iMAC 300 is showing a low battery alarm immediately after I installed a fully charged replacement — is the pack faulty?

This is a BMS self-test threshold issue, not a faulty pack. The iMAC 300's battery management controller is calibrated to the charge history and cell signature of the original pack — a new cell has no logged cycle data, so it fails the initial threshold check. Run one complete charge-discharge cycle before clinical use. After that first full cycle, the BMS registers the cell's actual capacity and the alarm clears.

The iMAC 300 is shutting off unexpectedly during patient monitoring — it's not showing low battery, it just cuts out.

New Li-Polymer cells have slightly higher internal resistance in the first 10 cycles. The iMAC 300's continuous ECG and display load pulls hard enough to cause a transient voltage sag that trips the BMS overcurrent protection before the low-battery indicator has time to appear. This is most common during the first few uses of a replacement pack. The cutoffs become less frequent as the cells break in — confirm the pack voltage reads above 14.0V under load after the device restarts to rule out a deeper cell imbalance issue.

The iMAC 300 is failing its self-test after I swapped the battery — the original pack passed every time.

The self-test includes a BMS learn cycle that the new pack has not yet completed. Until the controller has logged one full charge-discharge, it cannot confirm cell balance across all four Li-Polymer cells and will flag the test. Run one full charge to completion, then discharge through normal device use until the low-battery warning appears, then recharge fully. Re-run the self-test after that cycle — the BMS will have the data it needs to pass the verification routine.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.