Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Sonim BAT-02300-01S XP3 Plus Replacement Battery 3.85V 1400mAh

Up to 20% off
New arrival
Sale priceFrom $39.99 USD Regular price $49.99
Shipping calculated at checkout.
Fits Sonim XP3 Plus and XP3900 smartphones, replacing OEM battery BAT-02300-01S.
3.85V, 1400mAh Li-Polymer cell delivers sustained voltage under modem and display load.
Connector slides vertically into the battery slot with no locking tab interference required.
We bench-tested this cell on the XP3 Plus charge IC — BMS accepted full charge cycle without fault codes.
On first use after installation, complete one full discharge-charge cycle before enabling fast charging to recalibrate the fuel gauge IC against the new cell's discharge curve.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.85V

Amp

1400mAh

Sonim XP3 Plus / XP3900 — 3.85V Li-Polymer Replacement Battery (BAT-02300-01S)

This 3.85V, 1400mAh Li-Polymer battery replaces part number BAT-02300-01S in the Sonim XP3 Plus and XP3900 rugged smartphones. It fits both models directly, restoring power to a device built for industrial and outdoor use. Capacity is 1400mAh (5.39Wh) — matching the factory specification.

  • XP3 Plus and XP3900 compatibility: Both models share the same battery bay dimensions, connector pinout, and BMS handshake protocol. The same cell works across both variants without modification.
  • Bench tested on actual hardware: We cycled this battery through charge and discharge on the XP3 platform. The BMS responded correctly to charge termination, and the fuel gauge IC accepted the cell without triggering a fault state.
  • First-cycle fast charge protocol: On first use after installation, disable fast charging and run one complete discharge-charge cycle at standard current. This lets the fuel gauge IC recalibrate its coulomb counter against the new cell's discharge curve before high-current charging begins on an uncalibrated cell.

Sudden shutdown at 20–30% on the XP3 Plus after a cell swap

This happens because the fuel gauge IC is still mapped to the old cell's discharge curve. The new cell hits a voltage cliff — typically around 3.5V under modem or display load — before the reported percentage reaches zero. The phone shuts down to protect the cell, even though the gauge shows charge remaining. One full discharge-charge cycle at standard current resets the coulomb counter and brings the percentage readout back in line with actual cell voltage.

XP3 Plus not powering on after sitting in storage

Li-Polymer cells left discharged in storage can drop below 2.5V per cell, which triggers a BMS lockout — the battery stops responding entirely to protect against cell damage. The phone will not boot and may not show a charging indicator when you plug in. Connect to a wall charger rated at 5V and leave it for 20–30 minutes without pressing any buttons; the BMS recovery circuit needs sustained low-current input to exit lockout. If the device still shows no sign of life after that window, check the charger is delivering at least 5V 1A before drawing any other conclusions.

Compatible Models

XP3 Plus XP3900

Replaces Part Numbers

BAT-02300-01S

Technical Specifications

Voltage3.85V
Amp Hours1400mAh
Capacity1400mAh
Rate5.39Wh
Net Weight29g /1.02 oz
Gross Weight54g /1.90 oz
Approximate Weight54g /1.90 oz
Dimension 54.90 x 40.00 x 7.80mm

Product Highlights

  • Brand: Sonim
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-Polymer
  • Battery Type: Li-Polymer
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Sonim XP3 Plus shuts off at around 25% battery — why does it keep doing this on the new cell?

The fuel gauge IC was calibrated to your original cell's discharge curve, not the replacement. When the new cell's voltage drops under modem or screen load, it hits a cutoff point the gauge hasn't mapped yet — so the phone shuts down while still showing charge remaining. Run one full discharge down to automatic shutdown, then charge uninterrupted to 100% without fast charging enabled. After that single cycle the coulomb counter recalibrates and the percentage readout tracks the actual cell voltage correctly.

Fast charging stopped working after I fitted the BAT-02300-01S — the XP3 Plus is only charging slowly now.

On the first cycle after a cell swap, the BMS on the new cell may not immediately accept the handshake required for high-current charging. This is normal — the charge IC defaults to standard current until it can verify the cell is within safe parameters. Charge the phone fully once at standard rate without interrupting the session. On the second cycle, fast charging should resume; if the XP3 Plus still won't accept fast charge after two full cycles, check that the cable and adapter support the correct voltage and current for the device's charge protocol.

The battery percentage on my XP3 Plus is jumping around erratically — it went from 60% to 41% in two minutes without me using the phone.

Erratic percentage jumps are a fuel gauge IC recalibration symptom, not a sign the cell is faulty. The coulomb counter is comparing live cell voltage against a stored discharge curve that no longer matches the new cell's characteristics. The gauge corrects in large steps until it builds an accurate profile. Let the battery discharge naturally to automatic shutdown, then charge to 100% in one uninterrupted session at standard current — the IC will write a new discharge curve and the percentage readout will stabilise from the next cycle onward.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.