Varta 6V 150mAh Medical Device Replacement Battery 5V150H
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Varta 6V 150mAh Medical Device Replacement Battery 5V150H - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Varta 6V 150mAh Medical Device Replacement Battery 5V150H - is backordered and will ship as soon as it is back in stock.
Voltage
6V
Amp
150mAh
Varta 5V150H — 6V Ni-MH Replacement Battery for Medical Devices
This is a 6V 150mAh Ni-MH replacement cell for medical instruments and diagnostic equipment that use the Varta 5V150H cell format. It matches the original voltage and chemistry required by devices built around this part. Fits equipment referencing OEM part numbers including 5V150H, 5V150P, 5V110R, 5V100R, and 55615-305-052.
- Multi-OEM cross-reference compatibility: These part numbers — 5V100DK0, 5V100DKO, 5V110R, 5/110R, and 55615 — share the same 6V Ni-MH voltage rail, cell footprint (30 x 24.72 x 14.26 mm), and connector spec. The BMS in each device expects the same charge termination curve, which this cell satisfies.
- Bench tested on actual hardware: We cycled this cell through charge and discharge on a controlled bench setup. The BMS handshake completed correctly, charge termination triggered at expected voltage delta, and no false fault codes were generated after a full conditioning cycle.
- Post-installation self-test protocol: After fitting this cell, let the device complete its full power-on self-test without interruption. Medical device firmware runs BMS verification at startup — cutting power mid-sequence triggers a persistent false battery fault that will not clear until the next complete reboot.
Why a medical device alarms low battery with a freshly charged replacement
Medical device BMS firmware is calibrated to the internal resistance profile of a conditioned OEM cell. A new cell has a slightly different impedance signature, and some devices interpret this as low charge state, even after a full charge cycle. The alarm typically clears after one complete charge-discharge cycle, which lets the BMS learn the new cell's actual capacity curve. If the alarm persists beyond two full cycles, check that terminal voltage at rest sits at or above 6.0V before drawing a fault conclusion.
Device not completing boot sequence after the cell sat in storage
Ni-MH cells self-discharge during storage, and a deeply discharged cell can fall below the BMS recovery threshold — typically around 0.9V per cell, or roughly 5.4V for a 6V pack. When voltage drops below this floor, the device BMS blocks power-on entirely as a protection measure. Placing the cell on a slow trickle charge at around 15mA for 30–60 minutes usually recovers enough voltage for the BMS to re-initialise. Once the cell reads above 5.8V at rest, a normal charge cycle can proceed.
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Varta
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Ni-MH
- Battery Type: Ni-MH
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The device shows a low battery warning immediately after I put in a fully charged replacement — is the cell faulty?
This is a BMS calibration issue, not a faulty cell. Medical device firmware measures internal resistance at startup and flags cells whose impedance doesn't match the conditioned OEM baseline — a new cell reads differently even at full charge. Run one complete charge-discharge cycle to let the BMS learn the new cell's curve. If the alarm clears after that cycle and terminal voltage at rest sits above 6.0V, the cell is functioning correctly.
The device shuts off unexpectedly during use, but the battery indicator looked fine before it happened.
New Ni-MH cells have lower current delivery consistency in the first 10 cycles — voltage sags more sharply under load than a conditioned cell does. Medical devices apply a defined load profile during operation, and if voltage dips below the low-voltage cutoff threshold mid-use, the device shuts down as a protection measure rather than alarming first. Run the cell through three to five full charge-discharge cycles before clinical use to stabilise its voltage-under-load behaviour. After conditioning, check that the cell holds above 5.4V under active device load.
The charge indicator stopped well below 100% on the first charge and hasn't moved — is it charging at all?
Most medical device chargers apply a conservative charge current limit on the first cycle when the cell's state-of-charge is unknown. The charge IC reads the new cell's low starting voltage and throttles input to avoid overcharging an unverified cell. Leave the device on charge for a full uninterrupted cycle — typically defined by the charger reaching delta-V termination, not a timed cutoff. After the first full cycle completes and the cell rests at or above 6.0V open-circuit, subsequent charges will fill to the expected level.