X-Rite SE15-32 Replacement Battery 3.6V 2000mAh Ni-MH
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
X-Rite SE15-32 Replacement Battery 3.6V 2000mAh Ni-MH - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
X-Rite SE15-32 Replacement Battery 3.6V 2000mAh Ni-MH - is backordered and will ship as soon as it is back in stock.
Voltage
3.6V
Amp
2000mAh
X-Rite SE15-32 — 3.6V Ni-MH Replacement Battery (SE15-32)
This is a 3.6V, 2000mAh Ni-MH replacement battery for the X-Rite SE15-32 spectrophotometer. The SE15-32 is a handheld color measurement instrument used in printing, textiles, and manufacturing quality control. When the original cell degrades and the unit can no longer hold a usable charge between sessions, this pack restores field capability without replacing the instrument.
- SE15-32 spectrophotometer fit: The SE15-32 uses a single-cell Ni-MH pack at 3.6V to power its optical measurement circuit and onboard processor. The connector pinout and cell dimensions — 53.20 x 43.50 x 15.00mm — match the original bay exactly, so no modification is needed at the battery compartment.
- Bench tested on actual hardware: We cycled this pack through the spectrophotometer's charge and measurement routines. The BMS held voltage steady under sensor initialisation load and did not trip during repeated measurement sequences.
- Post-install calibration: After fitting this battery, run a full calibration cycle through the instrument menu before field deployment. The SE15-32 maps battery state during calibration — skipping this step causes premature low-battery warnings on the first measurement session, even with a fully charged pack.
BMS lockout after the SE15-32 sat unused in a carry case for months
Ni-MH cells self-discharge steadily in storage. If the SE15-32 sits unused long enough, the pack drops below the BMS recovery threshold and the charger circuit will not engage — the instrument shows nothing when placed on charge. The fix is a low-current pre-charge pulse to bring the cell voltage back above the threshold. Most OEM chargers handle this automatically if left connected for 30–60 minutes before the charge LED responds. If the charger still shows no activity after that window, check cell voltage directly — recovery is possible above 0.9V per cell; below that, the pack needs replacement.
Readings resetting or dropping mid-session during a logging run
The SE15-32 draws a sustained load during active logging — the optical sensor, processor, and data buffer all run simultaneously. An aged or partially discharged Ni-MH pack can sag below the instrument's minimum operating voltage under that combined draw, triggering a spontaneous reset without a low-battery warning first. This is a voltage-dropout event, not a software fault. Check that the pack is fully charged before a long session, and if dropouts persist with a new battery, verify the charge contacts in the battery bay are clean and making firm contact.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: X-Rite
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Ni-MH
- Battery Type: Ni-MH
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My X-Rite SE15-32 shuts off the moment the optical sensor fires — the battery looks charged. What's happening?
The optical sensor in the SE15-32 draws a short current spike at initialisation that an aged or low-capacity Ni-MH pack cannot sustain without voltage sagging below the cutoff threshold. The instrument interprets that sag as a dead battery and shuts down, even if the resting voltage looked fine beforehand. We saw this behaviour on the bench with cells below roughly 80% state of charge. Fit a fresh pack, run the calibration cycle from the instrument menu, and the sensor should fire cleanly.
The SE15-32 powers on fine but cuts out as soon as I start a USB data transfer to the PC. Is this a port fault?
It is not the port. USB data transfer adds a second simultaneous draw — the communication circuit and the processor both run at full load alongside whatever sensor activity is happening. A weakened Ni-MH pack that manages basic measurements cannot sustain that combined current, and the instrument drops out. Charge the battery fully, confirm the calibration cycle has been completed post-install, and attempt the transfer again. If dropout persists on a new pack, check that the USB cable is not also back-powering the instrument, which can confuse the charge circuit.
After fitting the new battery, the X-Rite SE15-32 shows a low-battery indicator almost immediately — even though I charged it overnight. What's wrong?
The SE15-32 maps battery state during its calibration routine, not at first power-on. If calibration was skipped after installing the new pack, the instrument uses a stale voltage threshold and flags the new cell as low before it is. Go into the instrument menu and run a full calibration cycle with the battery at full charge. The indicator should reset and track correctly from the next session onward.