Fits GP T111 baby monitor parent unit, replaces original 4.8V Ni-MH pack.
4.8V and 2000mAh capacity sustains eight-hour overnight monitoring with screen active.
Connector slides into vertical slot with locking tab — seats flush against circuit board.
Bench charge cycled three times; BMS accepted full capacity without voltage cutoff anomalies.
After battery swap, re-pair the parent unit with camera unit using the sync button — wireless link drops when power is fully interrupted.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

4.8V

Amp

2000mAh

GP T111 Baby Monitor — 4.8V Ni-MH Replacement Battery

This is a 4.8V, 2000mAh Ni-MH replacement battery for the GP T111 baby phone monitor. It fits the parent unit handset and restores charging capacity when the original cell has deteriorated. Voltage and capacity match the factory specification exactly.

  • T111 parent unit fit: The T111 parent handset runs on a 4.8V Ni-MH pack — a common voltage rail across baby phone parent units of this generation. The physical dimensions (57.71 × 50.79 × 14.58mm) and connector orientation match the original cell. No modification needed to seat it in the battery bay.
  • Bench tested on actual hardware: We cycled this battery through charge and discharge on the T111 parent unit. The cell accepted a full charge without thermal event, and the unit powered on cleanly at full capacity. BMS handshake completed normally with the charging circuit.
  • Re-pair after replacement: Once the parent unit loses power completely — as it does during a battery swap — the wireless link to the camera unit drops. After fitting this battery and powering on, hold the pairing button on both units until the link indicator confirms connection. This is a unit behaviour, not a battery fault.

Why the T111 parent unit drains overnight with the screen active

The T111 parent unit runs the display, radio receiver, and speaker circuit simultaneously during active monitoring. With the screen left on through the night, this is a sustained draw across all three subsystems — significantly higher than standby. A Ni-MH cell at end of life cannot sustain that draw across a full night shift. A fresh 2000mAh cell handles the load, but enabling the screen timeout in the unit's menu is the most effective way to reduce drain and extend intervals between charges.

Night vision drops out after battery swap

The camera unit's IR LEDs draw from their own power supply, but the parent unit must be at sufficient charge to maintain a stable radio link — and that link is what triggers the camera to hold night vision active. If the parent unit battery is low or freshly installed and not yet fully charged, the radio signal can dip below the threshold needed for a stable connection. The camera interprets a weak or intermittent link as a standby condition and cuts the IR array. Charge the parent unit fully before the first night use — this means reaching a resting voltage above 5.4V on the Ni-MH pack before relying on it overnight.

Compatible Models

T111

Technical Specifications

Voltage4.8V
Amp Hours2000mAh
Capacity2000mAh
Rate9.6Wh
Net Weight109.2g /3.85 oz
Gross Weight159.2g /5.62 oz
Approximate Weight159.2g /5.62 oz
Dimension 57.71 x 50.79 x 14.58mm

Product Highlights

  • Brand: GP
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The parent unit shows it's charging but won't hold charge for more than an hour — is the new battery faulty?

Ni-MH cells need two or three full charge-discharge cycles to reach rated capacity after a long period in storage or shipping. Run the parent unit until the low-battery indicator triggers, then charge it fully without interruption — repeat this twice. If the cell still won't hold charge after three conditioning cycles, it's a cell fault, but in most cases capacity comes up to spec within the first few cycles.

Parent unit turned on after battery swap but won't connect to the camera unit — no signal on screen

Cutting power to the parent unit clears the stored wireless pairing link. The camera unit and parent unit need to re-pair from scratch. Press and hold the pairing button on the camera unit first, then do the same on the parent unit within 30 seconds — the signal indicator on the parent screen confirms the link once it locks. This is standard behaviour any time the parent unit is fully power-cycled.

Range dropped noticeably after fitting the replacement battery — parent unit loses signal in rooms it reached before

The T111's radio transmitter output is voltage-sensitive — at less than a full charge, the parent unit runs at reduced transmit power, which cuts effective range. This is not a permanent change. Charge the parent unit fully before testing range, and confirm the resting voltage on the pack is above 5.4V before assuming a fault. A freshly installed Ni-MH cell that hasn't completed its first full charge will always show reduced range until it reaches full capacity.