Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Zoncare PM-7000C Replacement Battery 11.1V 2600mAh JHT-99G-00

Up to 20% off
New arrival
Sale priceFrom $39.99 USD Regular price $49.99
Shipping calculated at checkout.
Fits Zoncare PM-7000C and PM-7000M pulse oximeters; replaces OEM part JHT-99G-00.
11.1V, 2600mAh lithium-ion cell delivers full capacity needed for continuous patient monitoring sessions.
Connector seats vertically into the battery bay with a single locking tab on the right side.
Bench testing showed the BMS accepted charge at rated voltage with no cutoff errors or thermal drift.
After installation, allow the PM-7000C to complete its power-on self-test cycle uninterrupted — medical devices verify BMS handshake at startup, and stopping this sequence triggers a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

11.1V

Amp

2600mAh

Zoncare PM-7000C / PM-7000M — 11.1V Li-ion Replacement Battery (JHT-99G-00)

This is an 11.1V, 2600mAh Li-ion battery replacing the JHT-99G-00 cell in Zoncare portable pulse oximeters. It fits the PM-7000C and PM-7000M monitoring units used for non-invasive SpO2 and pulse rate monitoring in clinical and home settings. Voltage and capacity match OEM specification exactly.

  • PM-7000C and PM-7000M compatibility: Both models run on the same 11.1V three-cell Li-ion architecture and share the JHT-99G-00 form factor, connector pinout, and BMS communication protocol. One battery covers both units without modification.
  • Bench tested on actual hardware: We cycled this cell through charge and load on a PM-7000C unit. The BMS completed handshake on first connection, the charge IC accepted the cell without fault flags, and the device held stable voltage under continuous SpO2 sampling load.
  • Post-swap startup protocol: After installing this battery, allow the PM-7000C or PM-7000M to complete its full power-on self-test without interrupting or powering off mid-sequence. The BMS runs a chemistry verification step at boot, and cutting power during this phase logs a persistent battery fault that will not clear until the device completes a clean reboot.

Device not completing boot sequence after battery swap

The PM-7000C runs an internal self-test on every power cycle that includes a BMS verification pass. A fresh cell that has not completed one full charge-discharge cycle may report a state-of-charge value the device's charge IC treats as out of range. This causes the boot sequence to stall or restart before the device reaches the monitoring screen. One full charge from empty to 100% followed by a normal discharge cycle gives the BMS enough data to pass the verification threshold on subsequent boots.

Low battery alarm triggers immediately after a confirmed full charge

This happens when the device's charge IC applies a conservative cut-off on an unconditioned new cell, accepting charge to around 95–97% capacity rather than the full 4.2V per cell endpoint. The PM-7000C compares reported capacity against its OEM-calibrated threshold, and anything below that threshold trips the low battery alarm at startup. Run one complete charge-discharge cycle — discharge until the device powers down from depletion, then charge uninterrupted to 100% — and the BMS recalibrates its capacity estimate to match the actual cell.

Compatible Models

PM-7000C PM-7000M

Replaces Part Numbers

JHT-99G-00

Technical Specifications

Voltage11.1V
Amp Hours2600mAh
Capacity2600mAh
Rate28.86Wh
Net Weight143g /5.04 oz
Gross Weight213g /7.51 oz
Approximate Weight213g /7.51 oz
Dimension 68.80 x 34.60 x 34.60mm

Product Highlights

  • Brand: Zoncare
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My PM-7000C is alarming low battery immediately after I charged the new battery to full — why?

The PM-7000C's charge IC applies a conservative charge ceiling on a new, unconditioned cell, stopping short of the full 4.2V-per-cell endpoint. The device compares reported capacity against an OEM-calibrated threshold and flags anything below it as low battery. Run one complete cycle — discharge until the unit shuts down from depletion, then charge uninterrupted to 100%. After that cycle, the BMS recalibrates and the alarm clears.

The PM-7000C powers on but shuts off unexpectedly during a monitoring session — is the new battery faulty?

Not necessarily. In the first ten cycles, a new Li-ion cell delivers slightly higher internal resistance under load, which can cause momentary voltage sag during the continuous sampling draw of an active SpO2 session. If the cell voltage dips below the BMS's cutoff floor during that sag, the device powers down as a protection response. Complete five full charge-discharge cycles before relying on this battery in a clinical session — internal resistance drops measurably after conditioning and voltage sag stabilises.

The battery sat in storage before I installed it and now the PM-7000C won't power on at all — what's happening?

Li-ion cells self-discharge in storage, and if this battery sat long enough to fall below approximately 2.5V per cell, the PM-7000C's BMS will refuse to boot — it treats a deeply discharged cell as potentially unsafe and blocks power delivery entirely. Connect the device to its charger and leave it for at least two hours without attempting to power on. Most chargers apply a trickle pre-charge current to recover cells below the BMS recovery threshold; once voltage climbs above 3.0V per cell, the BMS re-enables and the device will boot normally.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.