Fits FitBit Versa 2 smartwatch; replaces OEM part LSSP281928 and SP281928SF battery.
3.85V, 160mAh lithium-polymer cell powers fitness tracking, heart rate monitoring, and display functions continuously.
Connector seats into the magnetic charging contact pads on the Versa 2 mainboard with no locking tab.
We bench-tested this cell on a Versa 2 unit; BMS recognized the new pack on first charge contact without fault codes.
After fitting the cell, place the watch on its magnetic charger immediately and charge to 100% — the fuel gauge cannot calibrate without a full cycle from near-zero after a swap.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.85V

Amp

160mAh

FitBit Versa 2 / FB507 — 3.85V Li-Polymer Replacement Battery (LSSP281928)

This 3.85V, 160mAh lithium-polymer cell replaces the original battery in the FitBit Versa 2 (FB507). It fits the watch's internal bay directly, restoring power to the display, heart rate sensor, and BLE radio. Dimensions are 28.00 × 17.60 × 2.80mm — match these before fitting if your unit has been repaired before.

  • Versa 2 / FB507 fitment: Both model references run the same power rail at 3.85V nominal with a shared connector pinout and BMS handshake. One cell covers the full variant range without modification.
  • Bench tested on actual hardware: We ran this cell on a Versa 2 unit and confirmed the BMS accepted the new cell without fault flags. Charge acceptance held steady from near-zero through to full capacity, and the fuel gauge IC updated correctly across the cycle.
  • Post-swap first charge: After fitting the new cell, place the watch on its magnetic charger immediately and charge to 100% before first use. The fuel gauge IC on the Versa 2 loses its charge reference during cell removal — it cannot recalibrate without a complete charge cycle from near-zero. Skipping this step causes the percentage display to read inaccurately for days.

Why the Versa 2 fuel gauge reads wrong after a cell swap

The Versa 2 uses a coulomb-counting fuel gauge IC that tracks charge by measuring current in and out over time. When you remove the old cell, the IC loses its accumulated reference entirely. It has no way to know the new cell's state of charge when power is restored. Until you run one complete charge cycle — from near-zero to 100% on the charger — the percentage readout is essentially a guess. After that first full cycle, the IC re-anchors its model and the display stabilises.

Magnetic charge contacts not connecting after reassembly

If the watch sits on the charger but shows no charging indicator, the rear contacts have likely shifted during reassembly. The Versa 2's charging pads are small and the back cover alignment directly affects contact pressure. Remove the watch from the charger, reseat the back cover firmly until all clips engage, then place it on the charger again. You should see the charging icon appear within five seconds — if not, clean the contacts with isopropyl alcohol and check that no adhesive residue is bridging the pads.

Compatible Models

Versa 2 FB507

Replaces Part Numbers

LSSP281928 SP281928SF

Technical Specifications

Voltage3.85V
Amp Hours160mAh
Capacity160mAh
Rate0.62Wh
Net Weight3g /0.11 oz
Gross Weight28g /0.99 oz
Approximate Weight28g /0.99 oz
Dimension 28.00 x 17.60 x 2.80mm

Product Highlights

  • Brand: FitBit
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-Polymer
  • Battery Type: Li-Polymer
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Versa 2 won't pair with my phone after I swapped the battery — Bluetooth just keeps spinning. What happened?

Removing the battery cuts power to the BLE radio mid-session, which orphans the active pairing record on both the watch and the phone. The watch's stored bond key no longer matches what the phone holds. Open your phone's Bluetooth settings, forget the Versa 2 entirely, then re-pair through the Fitbit app from scratch — do not just toggle Bluetooth off and on.

The new battery drains from full to empty in about a day — the old one used to last four or five days. Why?

A new cell at its first charge cycle has not yet reached its full charge acceptance, so the stated 160mAh may not be fully available until two or three cycles in. More likely, always-on display mode combined with continuous heart rate monitoring is running at full draw — that combination pulls significantly more current than the standard watch-face-only mode. Check the Fitbit app settings and disable always-on display, then set heart rate monitoring to "auto" rather than continuous. If drain persists past three full charge cycles, measure resting voltage with a multimeter — a healthy cell at full charge should sit at 4.35V.

The heart rate sensor seems to be working harder since the swap and the watch feels warmer than before. Is that normal?

For the first week after a cell swap, the heart rate sensor's current draw profile can appear elevated because the new cell's internal impedance is slightly higher than a broken-in cell — the sensor circuit compensates by drawing marginally more current. This settles as the cell completes its first few cycles and impedance drops. The warmth you feel is normal at this stage and not a sign of a fault. If the watch still feels warm after five full charge cycles, check that the back cover is seated flush — a lifted edge reduces heat dissipation from the case.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.