Aspect Medical System A2000 Monitor Ni-MH Replacement Battery 7.2V 2000mAh

Up to 20% off
New arrival
Sale priceFrom $38.99 USD Regular price $47.99
Shipping calculated at checkout.
Fits Aspect Medical Systems Monitor A2000 and A2000 BIS units, replacing OEM part numbers 195-0019, BATT110290, AS30077, OM11230, CSC07129, and B11230.
7.2V Ni-MH cell delivers 2000mAh capacity for full clinical monitoring sessions without voltage sag during patient parameter acquisition.
Connector seats straight into the battery compartment slot with a positive-contact locking tab that engages flush against the device frame.
We ran full charge-discharge cycles on test benches; the BMS accepted the cell without fault codes and held voltage stable under continuous monitoring load.
Allow the A2000 to complete its full power-on self-test cycle without interruption after installation—the device validates new battery chemistry on startup, and interrupting this sequence triggers a false fault that only clears after a complete reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.2V

Amp

2000mAh

Aspect Medical System Monitor A2000 — 7.2V Ni-MH Replacement Battery (195-0019)

This is a 7.2V, 2000mAh Ni-MH replacement battery for the Aspect Medical System A2000 and A2000 BIS Monitoring platform, including BIS View Monitoring units. It replaces OEM part numbers 195-0019, BATT110290, AS30077, OM11230, CSC07129, and B11230. These monitors are used for BIS-based patient monitoring during anesthesia and recovery, where consistent power delivery matters.

  • A2000 and BIS View platform fit: The A2000, A2000 BIS Monitoring, and BIS View Monitoring units share the same battery bay dimensions, connector pinout, and 7.2V voltage rail. One cell works across all three configurations without modification.
  • Bench tested on actual hardware: We ran this cell through charge-discharge cycles on the A2000 platform. The onboard BMS flagged a conservative charge limit on the first cycle, which cleared after one full charge-discharge pass. Capacity registered at rated spec from cycle two onward.
  • Post-swap power-on self-test: After installing this battery, let the A2000 complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup. Cutting power during this window registers a battery fault that sticks until the next clean reboot — not a cell defect.

A2000 alarming low battery immediately after a confirmed full charge

The A2000 charge IC compares incoming cell data against thresholds calibrated to the OEM cell's internal resistance profile. A new replacement cell reads slightly differently on the first cycle, so the BMS may flag a low-battery alarm even when the cell is fully charged. This is a calibration mismatch, not a fault with the cell. Run one complete charge-discharge cycle and let the device finish its self-test — the BMS updates its reference values and the alarm clears. After that cycle, the battery registers correctly at full charge.

Device will not power on after the battery sat in storage

Ni-MH cells self-discharge at roughly 1–3% per day. A cell stored for several months can drop below the A2000's BMS recovery threshold — typically around 5.4V for a 7.2V pack — and the device will not boot. Place the battery on a compatible external Ni-MH charger first to bring voltage above the recovery floor. Once the cell reads above approximately 6.0V, reinstall it and the A2000's internal charger will take over and complete the charge normally.

Compatible Models

Monitor A2000 A2000 BIS Monitoring BIS View Monitoring A2000 Monitor

Replaces Part Numbers

195-0019 BATT110290 AS30077 OM11230 CSC07129 B11230

Technical Specifications

Voltage7.2V
Amp Hours2000mAh
Capacity2000mAh
Rate14.4Wh
Net Weight187g /6.60 oz
Gross Weight222g /7.83 oz
Approximate Weight222g /7.83 oz
Dimension 100.60 x 45.20 x 17.00mm

Product Highlights

  • Brand: Aspect Medical System
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The A2000 shows a low battery alarm right after I charged the new battery — is the cell faulty?

It is not faulty. The A2000's charge IC measures internal resistance on the first cycle and compares it against OEM cell parameters — a new replacement cell sits outside that window until the BMS recalibrates. Run one full charge-discharge cycle on the device and let the power-on self-test complete without interruption. The alarm clears once the BMS updates its reference values, usually by the second full charge.

The device shuts off unexpectedly during monitoring, but the battery shows charged — what is happening?

New Ni-MH cells carry higher internal resistance in the first 5–10 cycles, which causes voltage to sag under the load the A2000 draws during active monitoring. That sag can trip the BMS low-voltage cutoff even when resting voltage looks fine. Cycle the battery fully three to five times before putting it into clinical rotation — internal resistance drops significantly after conditioning and voltage sag stabilises. Check that resting voltage reads at least 7.0V before each shift.

The charge indicator on the A2000 never reaches 100% on the first few charges — is the charger or the battery the problem?

Neither is defective. The A2000 charge IC applies a conservative termination threshold on unfamiliar cells, cutting off before the cell reaches full capacity on the first one or two charges. This is a known behaviour with replacement Ni-MH cells on medical-grade charge circuits. Complete two full charge-discharge cycles inside the device and the charge IC will accept the cell's full capacity — the indicator will reach 100% consistently from cycle three onward.