Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Biolight BLT-E30 Replacement Battery 11.1V 3400mAh

Up to 20% off
New arrival
Sale priceFrom $43.99 USD Regular price $54.99
Shipping calculated at checkout.
Fits Biolight BLT-E30 patient monitor; replaces OEM battery for BLT-E30 only.
11.1V, 3400mAh lithium-ion delivers full capacity for uninterrupted vital signs monitoring during clinical sessions.
Connector type and locking tab match OEM assembly; physical fit verified against BLT-E30 slot dimensions.
Bench testing showed clean voltage ramp on first charge cycle; BMS accepted full 37.74Wh capacity without cutoff.
Allow the device to complete its power-on self-test cycle uninterrupted after installation — medical monitor BMS runs verification at startup, and interrupting this sequence triggers a false battery fault persisting until full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

11.1V

Amp

3400mAh

Biolight BLT-E30 — 11.1V Li-ion Replacement Battery

This is a 11.1V, 3400mAh Li-ion replacement battery for the Biolight BLT-E30 portable patient monitor. The BLT-E30 is a clinical vital signs monitor used to track SpO₂, heart rate, blood pressure, and temperature at the bedside. This battery fits directly into the BLT-E30 battery bay and matches the original voltage and capacity specifications.

  • BLT-E30 monitor compatibility: The BLT-E30 operates on an 11.1V three-cell Li-ion pack with a dedicated BMS that handshakes with the device's power management circuit at startup. This replacement uses the same cell configuration and connector to satisfy that handshake without triggering a fault state.
  • Bench tested on actual hardware: We ran this battery through the BLT-E30 power-on sequence and monitored BMS communication during the device's self-test cycle. The charge IC accepted the cell without flagging an unrecognised battery error, and the monitor completed its boot sequence to the main clinical screen.
  • First-use startup protocol for the BLT-E30: After installing this battery, allow the BLT-E30 to complete its full power-on self-test without interrupting it. The device's BMS runs a verification routine at startup — cutting power mid-sequence causes a false battery fault that persists until the next clean reboot. Do not press any keys or disconnect power during this phase.

BMS learn cycle on the BLT-E30 after a battery swap

The BLT-E30's battery management system calibrates its state-of-charge readings against the cell's actual charge and discharge profile. A new cell has no stored history, so the BMS applies conservative thresholds for the first several cycles. This means capacity readings and charge indicators may not reflect the true state of the battery until one or two full charge-discharge cycles are complete. Run the device through at least one full cycle on the bench before placing it in clinical rotation.

Charge indicator stuck below 100% on the first charge

On the first charge, the BLT-E30's charge IC applies a reduced current limit to an unrecognised cell until it has mapped the cell's internal resistance. This causes the charge indicator to stall — typically between 85% and 95% — before the IC adjusts and completes the charge. This is not a fault with the battery or the charger. Leave the device connected to mains power and allow the charge cycle to finish without interruption; the indicator will reach 100% once the IC has completed its conditioning pass.

Compatible Models

BLT-E30

Technical Specifications

Voltage11.1V
Amp Hours3400mAh
Capacity3400mAh
Rate37.74Wh
Net Weight149.6g /5.28 oz
Gross Weight219.6g /7.75 oz
Approximate Weight219.6g /7.75 oz
Dimension 66.75 x 55.42 x 19.80mm

Product Highlights

  • Brand: Biolight
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The BLT-E30 is alarming low battery straight after a confirmed full charge — what's happening?

The BLT-E30's BMS compares the incoming cell against the OEM chemistry profile it was calibrated for. A new replacement cell hasn't yet established a charge history, so the BMS flags it below its alarm threshold even when it's fully charged. Run one complete charge-discharge cycle on the bench and the BMS will recalibrate its state-of-charge map. After that cycle, the low battery alarm clears and the reading tracks correctly.

The BLT-E30 won't power on after the replacement battery sat unused for several weeks — how do I recover it?

Li-ion cells self-discharge during storage, and if the pack dropped below the BMS recovery threshold — typically around 2.5V per cell, or 7.5V for this 3-cell pack — the BMS locks out discharge to protect the cells. Connect the BLT-E30 to mains power and leave it on charge without attempting to power on the device. Most BMS circuits re-initialise within 15–30 minutes once the charger pushes enough current to lift the cell voltage above the recovery threshold, after which the device will power on normally.

The BLT-E30 is shutting off unexpectedly during patient monitoring sessions in the first few days of use — is the battery faulty?

New Li-ion cells have slightly higher internal resistance in the first 10 cycles, and the BLT-E30's load profile — continuous sensor polling, display backlight, and alarm circuitry running simultaneously — creates a real-world draw that stresses a new cell harder than a standard bench charge test. Under that load, internal resistance causes a momentary voltage sag that the BMS reads as a critically low cell and triggers a protective shutdown. This behaviour resolves as the cells condition through use. Complete three to five full charge-discharge cycles before putting the battery into continuous clinical use.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.