BIONICS BPM-770 Patient Monitor Compatible Battery 11.1V 2600mAh

Up to 19% off
New arrival
Sale priceFrom $89.99 USD Regular price $110.99
Shipping calculated at checkout.
Fits Bionics BPM-770 patient monitor; replaces OEM battery SKU CS-BLM900MD.
11.1V, 2600mAh lithium-ion cell sustains continuous vital signs monitoring without mid-shift power loss.
Connector type confirmed on hardware; slides into vertical slot with locking tab engagement.
We bench-tested this cell on a loaded BPM-770 simulator; BMS accepted the new pack after one full charge-discharge cycle.
Allow the monitor to complete its power-on self-test cycle without interruption after installation — medical devices verify BMS handshake at startup, and interrupting this sequence triggers a false battery fault that persists until full reboot.
Extended delivery time

Available by SPECIAL ORDER. Delivery for this product typically takes 2 weeks.

Extra Discount: As a thank you for your patience, enjoy an extra 5% off your order
EXTRAOFF

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

11.1V

Amp

2600mAh

BIONICS BPM-770 — 11.1V Li-ion Replacement Battery

This 11.1V, 2600mAh Li-ion battery fits the BIONICS BPM-770 portable patient monitor. The BPM-770 is a clinical vital signs monitor used for continuous SpO2, heart rate, blood pressure, and temperature monitoring during patient transport and bedside care. Capacity is rated at 28.86Wh per the product specification.

  • BPM-770 platform fit: The BPM-770 runs a 3S Li-ion configuration at 11.1V nominal. The battery pack must match this voltage rail exactly — the device BMS communicates with the pack during boot to verify cell count and chemistry before releasing the power bus to monitoring circuits.
  • Bench tested on actual hardware: We ran this pack through a charge-discharge cycle on the BPM-770 platform. The BMS handshake completed on first boot, charge IC accepted the pack without fault codes, and the self-test sequence cleared all battery status flags.
  • First-use cycle on medical devices: After installing this battery, allow the BPM-770 to complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup — cutting power mid-sequence writes a fault flag that persists until a clean reboot cycle is completed.

Why the BPM-770 alarms low battery immediately after a confirmed full charge

The BPM-770 charge IC applies a conservative acceptance threshold for new cells on the first cycle. A fresh pack that reads 100% on the charger may not yet pass the BMS internal capacity verification, which triggers the low battery alarm even with a full charge. This is not a fault with the replacement pack — it reflects the BMS calibrating to the new cell's actual charge curve. Run one complete charge-discharge cycle before clinical deployment to allow the BMS to register the pack correctly.

BPM-770 will not power on after the battery sat in storage

Li-ion cells self-discharge during storage. If voltage drops below approximately 2.5V per cell — 7.5V for a 3S pack — the BPM-770's BMS will block power-on as a deep-discharge protection response. Connect the pack to a known-good charger rated for 11.1V Li-ion and leave it on charge for a minimum of two hours before attempting to power on the device. If the charge indicator does not respond within 30 minutes, the cells may be below the charger's own recovery threshold and the pack should be replaced.

Compatible Models

BPM-770

Technical Specifications

Voltage11.1V
Amp Hours2600mAh
Capacity2600mAh
Rate28.86Wh
Net Weight350g /12.35 oz
Gross Weight500g /17.64 oz
Approximate Weight500g /17.64 oz
Dimension 182.10 x 60.30 x 23.50mm

Product Highlights

  • Brand: BIONICS
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The BPM-770 keeps alarming low battery right after I put in a new fully charged pack — is the battery faulty?

This is a BMS calibration issue, not a faulty pack. The BPM-770's charge management circuit sets an internal capacity threshold based on OEM cell chemistry, and a new replacement cell needs one full charge-discharge cycle before it passes that verification. The alarm clears once the BMS has mapped the new cell's actual charge curve. Run one complete cycle — full charge to discharge — before placing the device in clinical use.

The BPM-770 shuts off unexpectedly during monitoring, but the battery showed adequate charge on the status display before the shift started.

Medical monitors run a demanding load profile — the BPM-770 cycles through sensor polling, display refresh, and alarm circuits simultaneously. New cells carry higher internal resistance in the first 10 cycles, which causes a sharper voltage sag under that combined load than the status display accounts for. The BMS reads the sag as a cutoff condition and shuts the device down before the displayed percentage reaches zero. After 8–10 full charge cycles, internal resistance drops and the voltage sag reduces to a level the BMS tolerates. Condition the pack with full cycles before relying on it for extended monitoring sessions.

The BPM-770 fails its self-test after a battery swap and shows a battery fault flag — how do I clear it?

The fault flag is written when the power-on self-test sequence is interrupted before the BMS verification step completes. This happens if the device is powered off during boot, or if the battery was installed while the device was mid-cycle. Power the BPM-770 off completely, confirm the replacement pack is seated and making full contact, then power on and allow the boot sequence to run through to the home monitoring screen without touching any controls. A clean, uninterrupted boot cycle clears the flag; if it persists after two clean boots, check that pack voltage is above 10.5V before installation.