Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

BLU Studio G Plus Replacement Battery 3.7V 1800mAh

Up to 21% off
New arrival
Sale priceFrom $23.99 USD Regular price $29.99
Shipping calculated at checkout.
Fits BLU Studio G Plus and S510 variants, replaces OEM part C826641280T.
3.7V 1800mAh lithium-ion cell delivers full charge capacity for standard smartphone operation without voltage sag under modem load.
Connector sits flush against the phone's battery contact springs — no adapter needed, slides straight into the original slot.
We bench-tested this cell in a Studio G Plus charger; the fuel gauge IC accepted the new BMS on the first complete cycle with no early cutoff.
On first use after installation, run one full discharge-charge cycle without fast charging enabled — this lets the coulomb counter recalibrate against the new cell's discharge curve before high-current charging resumes.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

1800mAh

BLU Studio G Plus — 3.7V Li-ion Replacement Battery (C826641280T)

This 3.7V, 1800mAh Li-ion battery replaces part number C826641280T in the BLU Studio G Plus. It also fits the S510, S510Q, and Grand Max variants that share the same battery bay dimensions and connector. Capacity is 1800mAh (6.66Wh), matching the original cell specification.

  • Studio G Plus / S510 series fit: These models share a common battery footprint — 82.00 x 64.90 x 4.07mm — along with the same connector pinout and BMS handshake protocol. Swapping across this group does not trigger a charge IC fault.
  • Bench tested on actual hardware: We ran this cell through full charge and discharge cycles on the Studio G Plus board. The BMS accepted the cell without fault codes, and the charge IC held steady throughout the cycle.
  • Fuel gauge recalibration on first use: After installation, disable fast charging and run one full discharge down to automatic shutdown, then charge uninterrupted to 100%. This gives the fuel gauge IC one complete data set against the new cell's discharge curve before high-current charging begins.

Sudden shutdown at 20–30% on the BLU Studio G Plus

This happens when the fuel gauge IC is still calibrated to the old cell's discharge curve. The new cell hits a voltage cliff under load — typically during screen-on or modem activity — before the reported percentage reaches zero. The phone's charge IC reads the voltage drop as a shutdown threshold, so the device powers off even though the gauge shows charge remaining. One full discharge-to-shutdown and uninterrupted recharge cycle resets the coulomb counter and resolves this.

Phone won't power on after the battery sat discharged in storage

Li-ion cells that drop below roughly 2.5V trigger a BMS lockout to prevent unsafe charging of a deeply discharged cell. The Studio G Plus will show no charge indicator and will not boot. Connect the phone to a wall adapter — not a PC USB port — and leave it undisturbed for 20–30 minutes. The charge IC trickle-charges the cell back above the BMS recovery threshold, after which the phone should show the charging screen and boot normally.

Compatible Models

Studio G Plus S510 S510Q Grand Max G110Q

Replaces Part Numbers

C826641280T

Technical Specifications

Voltage3.7V
Amp Hours1800mAh
Capacity1800mAh
Rate6.66Wh
Net Weight45.4g /1.60 oz
Gross Weight80g /2.82 oz
Approximate Weight80g /2.82 oz
Dimension 82.00 x 64.90 x 4.07mm

Product Highlights

  • Brand: BLU
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My BLU Studio G Plus shows the wrong battery percentage after I put in the new battery — is that normal?

Yes, and it's caused by the fuel gauge IC still referencing the old cell's discharge curve. The IC uses a coulomb counter that was calibrated to the worn-out original cell, so readings on a fresh cell are inaccurate. Run one full discharge to automatic shutdown, then charge to 100% without interruption. After that single cycle the fuel gauge recalibrates and percentage readings stabilise.

The phone feels warm near the battery area while charging — should I be concerned?

Mild warmth during the first few charge cycles on a new cell is expected. A fresh Li-ion cell has higher internal impedance than a used one, which causes the charge IC to dissipate slightly more heat as it works to push current in. If the phone becomes hot to the touch or charging cuts off early, stop and check that the charger output does not exceed the phone's rated input. Warmth that fades after the first two or three full cycles is not a fault.

Fast charging stopped working after I swapped the battery in my Studio G Plus — what happened?

The charge IC negotiates fast charge protocol on each new cell connection, and on the first cycle it sometimes defaults to standard charging while it reads the new BMS parameters. This is not a fault. Run one complete standard charge cycle to 100%, then unplug and reconnect — the IC re-negotiates and fast charging typically resumes. If it does not, confirm the adapter output is at least 5V/2A, as the Studio G Plus fast charge handshake requires adequate input voltage to trigger.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.