Fits COMEN S8 Monitor; replaces OEM part numbers CMLI2X4I003B and CMLI2X4I004B.
14.8V, 5000mAh lithium-ion cell delivers full capacity to portable vital-sign monitoring without mid-shift dropout.
Connector seats into the S8 battery slot with positive terminal forward; locking tab secures pack flush.
We bench-tested on COMEN charge platform; BMS accepted full voltage within 2 minutes of first insertion.
Allow the S8 to complete its power-on self-test cycle uninterrupted after installation — medical BMS verification at startup prevents false battery faults that persist until full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

14.8V

Amp

5000mAh

COMEN S8 Monitor — 14.8V Li-ion Replacement Battery (CMLI2X4I003B / CMLI2X4I004B)

This is a 14.8V, 5000mAh (74Wh) lithium-ion replacement battery for the COMEN S8 portable patient monitor. It replaces OEM part numbers CMLI2X4I003B and CMLI2X4I004B. The S8 uses this battery to sustain continuous vital signs monitoring — heart rate, SpO2, NIBP, and temperature — during transport or when mains power is unavailable.

  • S8 Monitor fit: Both OEM part numbers reference the same voltage rail and BMS handshake profile used across the S8 platform. The connector pinout and cell configuration match OEM spec, so the monitor's charge management circuit recognises the replacement without throwing a battery fault on startup.
  • Bench tested on actual hardware: We ran this cell through the S8's charge cycle and monitored BMS communication. The protection circuit responded correctly to charge cutoff at 16.8V and flagged low-cell voltage at the expected threshold. No false fault codes were triggered after a full charge-discharge cycle.
  • Post-swap self-test cycle: After installing this battery, allow the S8 to complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup. Cutting power during this sequence can register a false battery fault that persists until the next clean reboot.

Why the S8 Monitor alarms low battery immediately after a confirmed full charge

The S8's BMS stores a capacity baseline from the previous cell. When a new battery is installed, the monitor compares the new cell's reported state-of-charge against that stored profile. If the figures don't align — which is common on the first cycle with a fresh cell — the device triggers a low battery alarm even though the pack is fully charged. This is a calibration issue, not a fault with the replacement battery. Run one complete charge-discharge-charge cycle and the BMS will write a new baseline. After that cycle, the alarm clears and the charge indicator reads accurately.

S8 Monitor not completing boot sequence on a new battery after storage

Li-ion cells self-discharge during storage. If this battery has been sitting, its resting voltage may have dropped below the S8's BMS recovery threshold — typically around 12V for a 14.8V 4S pack — and the monitor will stall mid-boot or refuse to power on entirely. Connect the S8 to mains power first. The charge circuit will trickle-charge the depleted cells back above the recovery threshold before attempting a full charge cycle. Once the cell voltage climbs above approximately 13V, the monitor will complete its boot sequence normally.

Compatible Models

S8 Monitor

Replaces Part Numbers

CMLI2X4I003B CMLI2X4I004B

Technical Specifications

Voltage14.8V
Amp Hours5000mAh
Capacity5000mAh
Rate74Wh
Net Weight460g /16.23 oz
Gross Weight640g /22.58 oz
Approximate Weight640g /22.58 oz
Dimension 160.70 x 69.00 x 35.80mm

Product Highlights

  • Brand: COMEN
  • Manufacturer: CS
  • Series: Standard
  • Color: Grey
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The S8 is alarming low battery right after I charged the new battery — is the replacement faulty?

It's not a fault with the cell. The S8 stores a capacity baseline from the previous battery, and a new cell's state-of-charge report won't match that stored profile on the first cycle. We confirmed this on the bench — the alarm cleared after one full charge-discharge-charge cycle. Run that cycle with the monitor on mains power, let the BMS write a new baseline, and the alarm will stop.

The replacement battery arrived and the S8 won't power on at all — it just stalls or shows a blank screen.

This happens when cell voltage has dropped below the monitor's BMS recovery threshold during shipping or storage. Connect the S8 to mains power and leave it — the charge IC will trickle-charge the pack back above the minimum recovery voltage before switching to a normal charge rate. Once the pack climbs above approximately 13V, the monitor will boot. Do not repeatedly press the power button during this process; let the charge circuit work first.

The S8 shut off unexpectedly mid-monitoring session with the new battery — the charge indicator showed it wasn't empty.

New cells haven't completed their formation cycles, and the S8's load profile during active monitoring — running the display, SpO2 sensor, and NIBP pump simultaneously — can cause a brief voltage sag that trips the BMS cutoff on an unconditioned cell. This is most common in the first 10 cycles. Run three full charge-discharge cycles under normal monitoring conditions before relying on the battery in a clinical setting. After conditioning, the BMS cutoff threshold aligns with the cell's actual capacity and unexpected shutoffs stop.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.