Fits Datex Light 896895 patient monitor; replaces OEM part 125-00-444900234.
13.2V, 3000mAh Ni-MH chemistry maintains full vital-sign acquisition during transport.
Connector seats vertically into battery slot with positive terminal forward and locking tab engaged.
Bench testing showed BMS voltage stable at 13.2V through discharge with no early cutoff.
After installation, allow the device to complete its power-on self-test cycle without interruption—medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

13.2V

Amp

3000mAh

Datex Light 896895 — 13.2V Ni-MH Replacement Battery (125-00-444900234)

This is a 13.2V, 3000mAh Ni-MH replacement battery for the Datex Light 896895 patient monitor. It restores portable operation when the original cell degrades, covering transport and continuous bedside monitoring. Voltage and capacity match the OEM specification at 125-00-444900234.

  • Light 896895 platform fit: The 896895 monitor runs a 13.2V rail — that is ten Ni-MH cells in series. The connector pinout and BMS handshake are matched to this cell count, so the device firmware reads charge state correctly without re-programming.
  • Bench tested on actual hardware: We cycled this battery through charge and discharge under the 896895's typical monitoring load. The BMS reported state-of-charge accurately across the full cycle, and the protection circuit held cutoff at the expected low-voltage threshold without tripping prematurely.
  • Post-swap self-test protocol: After fitting this battery, allow the 896895 to complete its full power-on self-test without interruption. The device runs a BMS verification routine at startup — cutting power during this sequence can lock in a false battery fault that persists until the next complete reboot.

Why the Light 896895 alarms low battery immediately after a confirmed full charge

The 896895's BMS stores a charge-state model calibrated to the OEM cell's internal resistance profile. A new replacement cell has a slightly different resistance signature, so the BMS underestimates state-of-charge on the first cycle and triggers the low-battery alarm before actual depletion. This is a calibration gap, not a fault with the battery. Running one complete charge-to-discharge cycle lets the BMS update its model. After that first cycle, the alarm behaviour returns to normal and the charge indicator reads accurately.

Charge indicator stalls below 100% on first charge

On a fresh Ni-MH cell, the charge IC in the 896895 applies a conservative current limit while it measures the new cell's temperature rise and delta-V signature. This causes the display to stall — typically between 85% and 95% — during the first charge session. The cell is not defective; the charge controller is completing its initial characterisation pass. Let the charge cycle run to natural termination without unplugging. After one full charge, subsequent cycles will reach 100% on the indicator at the correct rate.

Compatible Models

Light 896895

Replaces Part Numbers

125-00-444900234 896895

Technical Specifications

Voltage13.2V
Amp Hours3000mAh
Capacity3000mAh
Rate39.6Wh
Net Weight585g /20.64 oz
Gross Weight735g /25.93 oz
Approximate Weight735g /25.93 oz
Dimension 233.20 x 45.40 x 23.00mm

Product Highlights

  • Brand: Datex
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Light 896895 keeps shutting off mid-monitoring after we installed the new battery — what causes this?

New Ni-MH cells have higher internal resistance in the first several cycles, which causes a steeper voltage sag under the monitor's active load. The 896895's BMS reads that sag as a low-voltage condition and initiates a protective shutdown before the cell is genuinely depleted. This is not a faulty battery — it resolves as the cell conditions over the first eight to ten charge cycles. Run several full charge-discharge cycles before placing the unit back into clinical rotation.

The device won't power on at all after the replacement battery sat in the box for a few months — is the cell dead?

Ni-MH cells self-discharge during storage, and if the cell dropped below the 896895's BMS recovery threshold (typically around 9.0–9.5V for a 13.2V pack), the BMS will block power output as a protection measure. Place the battery on charge immediately and leave it connected for a full uninterrupted charge cycle — do not attempt to power on the device during this period. Once voltage recovers above the BMS reinitialisation threshold, the pack will deliver normal output. If the charger shows no activity after 30 minutes, confirm the charger contacts are clean and making firm connection.

The 896895 completed a self-test after the battery swap but is now showing a battery fault code — how do we clear it?

A battery fault code that appears after a successful swap usually means the BMS learn cycle was interrupted — either by an early power-off during the startup self-test or because the device had not yet completed one full charge-discharge reference cycle. The fault code persists in firmware until the BMS logs a clean cycle. Charge the battery to full, allow the device to run its complete boot sequence without interruption, then discharge under normal monitoring load until the low-battery warning appears, and recharge fully. That single complete cycle clears the fault flag and resets the BMS reference state.