Dyson G5 Detect Absolute 36V Replacement Battery 507147-07
This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Dyson G5 Detect Absolute 36V Replacement Battery 507147-07 - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Dyson G5 Detect Absolute 36V Replacement Battery 507147-07 - is backordered and will ship as soon as it is back in stock.
Voltage
36V
Amp
2500mAh
Dyson G5 Detect Series — 36V Li-ion Replacement Battery (507147-07)
This is a 36V, 2500mAh Li-ion replacement battery for the Dyson G5 Detect Absolute, G5 Detect Fluffy, Gen5 Outsize, and related G5 Detect models. It matches OEM part numbers 507147-07, 512048-07, 972382-01, 972382-03, and 972382-04, covering SV23 and SV24 platform vacuums. Swap it in when the original cell no longer holds a useful charge.
- G5 Detect platform compatibility: The SV23 and SV24 motor boards share the same 36V power rail and use an identical BMS handshake protocol. That is why one battery pack covers the Absolute, Fluffy, and Outsize variants — the connector pinout and communication lines are the same across all G5 Detect configurations.
- Bench tested on actual hardware: We ran this cell through full charge and discharge cycles on the SV23 platform. The BMS negotiated correctly with the vacuum's motor controller, voltage held steady under the high-torque DLS motor load, and the protection circuit triggered cleanly at the low-cell cutoff threshold without nuisance trips.
- Dock charging habit on G5 Detect vacuums: Do not leave the vacuum on the charging dock permanently. G5 Detect units on continuous dock power develop capacity fade faster than units charged only when the battery is depleted. Charge to full, then remove the vacuum from the dock.
Cordless vacuum losing suction before the battery indicator reaches low
This happens when the motor draws more current than the battery can supply at its actual state of charge, causing a voltage sag that the indicator does not reflect accurately. A partially blocked filter is the most common trigger — restricted airflow forces the DLS motor to work harder, pulling current spikes the BMS was not expecting. The battery is not necessarily failing; the motor load is the real cause. Clean or replace the filter first, then retest — if suction stabilises, the battery cell is fine.
Motor cuts out mid-use then recovers after a few seconds
This is a BMS overcurrent trip, not a dead battery. When sustained restricted suction forces the motor to draw above the protection threshold — typically triggered by a blocked filter or a tangled brush bar — the BMS shuts the output rail and resets after a short thermal pause. The vacuum restarts because the BMS clears the fault once current demand drops. Clear the blockage, check that the brush bar spins freely, and confirm the filter is clean before putting the vacuum back into use.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Dyson
- Manufacturer: CS
- Series: Standard
- Color: Grey
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My Dyson G5 Detect suction drops noticeably partway through a clean but the battery light still shows full — what's happening?
This is voltage sag under motor load, not a faulty indicator. When the filter is partially blocked, the DLS motor draws higher current to compensate, pulling the pack voltage below the level needed to sustain full suction — even though the charge indicator still reads high. Clean the filter thoroughly and check the brush bar for obstructions before assuming the battery is at fault. If suction holds steady after cleaning the filter, the cell is working correctly.
The motor on my G5 Detect cuts out for a few seconds then restarts on its own — is this the battery failing?
Most likely not. That cut-and-recover pattern is a BMS overcurrent trip — the protection circuit shuts the output rail when sustained current draw exceeds the threshold, then resets once the demand drops. It happens most often when the brush bar is tangled or the filter is restricted, forcing the motor to pull more current than rated. Clear the blockage, spin the brush bar by hand to confirm it moves freely, then run the vacuum again. Persistent trips with a clean filter and clear brush bar would point to a degraded cell.
My new replacement battery charges fine but the G5 Detect runs for noticeably less time than the original did when it was new — why?
A partially blocked post-motor filter is the most overlooked cause. Restricted airflow makes the DLS motor work harder throughout the entire clean, drawing higher sustained current and depleting the 2500mAh pack faster than the rated draw would. Remove and wash both the pre-filter and post-motor filter, let them dry fully for at least 24 hours, then retest. If runtime improves, the filters were the issue — not the replacement cell.