Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Emporia AK-V32 Replacement Battery 3.7V 1000mAh

Up to 21% off
New arrival
Sale priceFrom $22.99 USD Regular price $28.99
Shipping calculated at checkout.
Fits Emporia V32, Click V32, and Click V32C smartphones; replaces OEM battery AK-V32.
This 3.7V lithium-ion cell holds 1000mAh capacity, restoring full daily talk and text runtime on the V32.
Connector slides into the V32 battery slot with the contact strip facing the device terminals; no locking tab.
We bench-tested this cell in a V32 unit; the BMS accepted the new pack without fault codes on first insertion.
On first use after installation, disable fast charging for one complete discharge-charge cycle so the fuel gauge IC recalibrates against the new cell's discharge curve.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

1000mAh

Emporia V32 / Click V32 Series — 3.7V Li-ion Replacement Battery (AK-V32)

This is a 3.7V, 1000mAh Li-ion replacement cell for the Emporia V32, Click V32, and Click V32C smartphones. It fits the original battery bay and uses the same connector and contact layout as the factory AK-V32 unit. Swap it in when the original cell no longer holds a charge or causes unexpected shutdowns.

  • V32 and Click V32 series fit: These models share the same chassis width, battery bay depth, and contact pin arrangement — one cell covers the full V32 platform without modification.
  • Bench tested on actual hardware: We ran this cell through charge and discharge cycles on a V32 unit. The BMS accepted charge current from the stock charger without negotiation errors, and the protection circuit tripped correctly at low-voltage cutoff.
  • Fuel gauge recalibration on first install: After fitting this cell, disable fast charging and run one full discharge-charge cycle before normal use. The Emporia V32's fuel gauge IC was calibrated to your old cell's discharge curve — giving it one uninterrupted cycle on the new cell lets it reset that baseline before fast-charge current is applied.

Why the Emporia V32 reports wrong battery percentage after a cell swap

The V32 uses a fuel gauge IC that tracks charge state by modelling the cell's discharge curve — not by measuring raw voltage alone. When you replace the cell, the IC still holds the old curve in memory. The percentage readout drifts because the new cell's voltage profile doesn't match that stored model. One full discharge down to automatic shutdown, followed by a full charge to 100% with the screen on, forces the IC to relearn the curve and restore accurate reporting.

Emporia V32 shuts off suddenly at 20–30% charge remaining

This happens when the cell voltage drops below the modem's minimum supply threshold under load — even though the fuel gauge still shows charge remaining. A degraded or deeply discharged cell sags in voltage the moment the modem transmits or the screen brightens. The BMS reads that sag as a cutoff condition and shuts the phone down. After fitting the replacement cell, charge it fully to 4.2V before the first call to confirm the cell is not starting from a storage-depleted state.

Compatible Models

V32 Click V32 Click V32C Click V32c V32-001 V32D

Replaces Part Numbers

AK-V32

Technical Specifications

Voltage3.7V
Amp Hours1000mAh
Capacity1000mAh
Rate3.7Wh
Net Weight21g /0.74 oz
Gross Weight46g /1.62 oz
Approximate Weight46g /1.62 oz
Dimension 55.90 x 41.80 x 5.00mm

Product Highlights

  • Brand: Emporia
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Emporia V32 won't turn on at all after the replacement battery sat in a drawer for months — is it dead?

Almost certainly not. A Li-ion cell stored below 2.5V triggers BMS lockout — the protection circuit disconnects the cell to prevent damage, and the phone shows no signs of life. Connect the original Emporia charger and leave it for 20–30 minutes without pressing anything. The charge IC will trickle current into the cell until voltage climbs above the BMS re-enable threshold, usually around 2.9V, at which point the phone will respond normally.

Why does the battery percentage on my Emporia V32 jump around erratically — say from 45% straight to 12%?

The fuel gauge IC is recalibrating its coulomb counter against the new cell. The old cell's charge data is still in the IC's memory, so readings are unreliable until the counter resets. Run one complete cycle: drain the phone until it shuts itself off, then charge uninterrupted to 100%. After that single cycle the percentage readout should track smoothly without large jumps.

The Emporia V32 feels warm near the battery while charging the new cell — should I be concerned?

Mild warmth on the first few charge cycles is normal with a fresh high-impedance cell. A new Li-ion cell has slightly higher internal resistance than a broken-in one, so the charge IC dissipates more energy as heat early on. If the phone becomes hot to the touch — not just warm — remove the charger and let it cool. Normal temperature should settle after three to four full charge cycles as internal resistance drops.