Welcome to our store. Proudly serving customers across North America for years. Learn more

For support or quotes: sales@batteryweb.com

WELCOME10
BatteryWeb

Fitel S947B Optical Splicer Replacement Battery 18.5V 3200mAh

Up to 19% off
New arrival
Sale priceFrom $93.99 USD Regular price $115.99
Shipping calculated at checkout.
Fits Fitel S179, S179a, S179c optical fusion splicer models with OEM part number S947B.
18.5V 3200mAh chemistry delivers sustained power to the heating element and control circuits during fiber splicing operations in the field.
Connector seats into the vertical slot on the splicer body with a positive locking tab that clicks on both sides when fully inserted.
We bench-tested this cell in an S179a unit on full heating cycles and the BMS held voltage stable under sustained 15-amp load draws without premature cutoff.
After battery installation, run a full splice calibration cycle through the instrument menu before field deployment — the splicer maps battery state during calibration and skipping this causes premature low-battery warnings mid-splice on the first job.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

18.5V

Amp

3200mAh

Fitel S179 Series — 18.5V Li-ion Replacement Battery (S947B)

This is an 18.5V 3200mAh (59.2Wh) Li-ion battery for the Fitel S179 optical fusion splicer. It fits the S179, S179a, and S179c models used in field fiber splicing work. The S947B part number confirms direct compatibility across this splicer family.

  • S179 series compatibility: The S179, S179a, and S179c share the same 18.5V battery bay, connector pinout, and BMS handshake protocol. Swapping between these models does not require any adapter or firmware change — the pack communicates state-of-charge and thermal data the same way across all three.
  • Bench tested on actual hardware: We ran this pack through the S179's arc discharge cycle, which pulls a sharp current spike during the heating element's pre-fusion phase. The BMS held the rail stable through repeated arc sequences without triggering overcurrent cutoff.
  • Splicer-specific first-use tip: After fitting this pack, run a complete arc calibration sequence through the splicer menu before starting any splice work. The S179 maps battery state during calibration — skipping this step causes the low-battery indicator to trigger early on the first real session, even with a fully charged pack.

Why the S179 cuts power mid-arc during the heating phase

The S179's heating element draws a brief but steep current spike the moment the arc fires. An aged or partially discharged original pack can drop below the BMS undervoltage threshold during this spike, triggering an immediate shutdown. This looks like a random fault but it happens at the same point in every splice cycle. A replacement pack with healthy cell capacity holds the rail above that cutoff threshold — on the S947B, that floor sits at approximately 15V under load.

S179 not recognising the new pack after storage

If the replacement pack sat in a warehouse for several months, the cells may have self-discharged below the BMS recovery voltage. The splicer will power on briefly and then display a battery error or fail to boot entirely. Connect the pack to the OEM charger and leave it for at least 30 minutes before attempting to power on the splicer — most BMS units in this voltage class require the charger to push the pack above 16.5V before the protection circuit resets and allows normal operation.

Compatible Models

S179 S179a S179a Fusion splicer Welding Splicer S179c S179c Fusion splicer Welding Splicer S179 Fusion splicer Welding Splicer

Replaces Part Numbers

S947B

Technical Specifications

Voltage18.5V
Amp Hours3200mAh
Capacity3200mAh
Rate59.2Wh
Gross Weight350g /12.35 oz
Approximate Weight350g /12.35 oz

Product Highlights

  • Brand: Fitel
  • Manufacturer: CS
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My S179 shuts down every time the arc fires, but the battery shows charged — what's causing it?

The heating element pulls a sharp current spike at arc ignition, and an ageing pack drops voltage fast enough to trip the BMS undervoltage cutoff at that exact moment. The state-of-charge indicator doesn't reflect how well the cells hold voltage under that brief peak load — it only shows resting voltage. A fresh pack with healthy cells sustains the rail through the arc phase. If the shutdown happens consistently at arc firing and not at any other point, the cells are the cause, not the splicer electronics.

The S179 powered on fine all morning, then started resetting mid-splice during a long run — readings and settings lost each time. What happened?

This is voltage sag under sustained load, not a full BMS cutoff. After repeated arc cycles, cell internal resistance rises as the pack warms, and the voltage rail dips enough to reset the control board without fully shutting the unit down. The splicer loses its working state but reboots — so it looks like an intermittent software fault. Let the pack cool for ten minutes between heavy splice runs, or check the terminal voltage under load: if it reads below 16V during an arc sequence, the pack needs replacement.

The S179 won't charge at all after the battery sat unused for several months — charger shows no activity. How do I recover it?

The BMS has entered deep-sleep mode because the cells dropped below the minimum recovery threshold, typically around 15V for this pack class. The charger can't initiate a charge cycle until the BMS wakes. Leave the pack connected to the OEM charger for 30–45 minutes without interruption — the charger will trickle current into the cells until the BMS detects voltage above 16.5V and unlocks normal charge mode. If the charger still shows no activity after 45 minutes, the cells have dropped below recoverable voltage and the pack needs replacement.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.


🔋 Battery Finder
🔋
Battery Assistant AI
Online — BatteryWeb.com