Northern Virgo NT-L14S1P-PA Replacement Battery 14.8V 2600mAh
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Northern Virgo NT-L14S1P-PA Replacement Battery 14.8V 2600mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Northern Virgo NT-L14S1P-PA Replacement Battery 14.8V 2600mAh - is backordered and will ship as soon as it is back in stock.
Voltage
14.8V
Amp
2600mAh
Northern Virgo — 14.8V Li-ion Replacement Battery (NT-L14S1P-PA)
This is a 14.8V, 2600mAh (38.48Wh) lithium-ion replacement battery for the Northern Virgo portable medical device. It replaces OEM part numbers NT-L14S1P-PA, NT-LI4S1P-PA, 022-000069-00, and 022.01.000069-00. The battery restores power to the Virgo unit when the original cell depletes or fails.
- Virgo platform compatibility: All four OEM part numbers listed map to the same 14.8V four-cell lithium-ion configuration used across Virgo variants. The connector, BMS handshake protocol, and voltage rail are identical across these part numbers — swapping between them does not require firmware changes or calibration steps.
- Bench tested on actual hardware: We cycled this battery through the Virgo's full charge-discharge sequence and monitored BMS communication at each stage. The protection circuit responded correctly to charge termination and low-voltage cutoff without triggering false fault flags.
- Power-on self-test after installation: After fitting this battery, allow the Virgo to complete its full power-on self-test cycle without interruption. Medical devices run BMS verification at startup, and cutting power mid-sequence can register a false battery fault that persists until the next clean reboot.
Device not completing boot sequence after battery swap
The Virgo runs a BMS handshake during startup to verify cell chemistry and state of charge. A new replacement cell that has partially self-discharged during storage can report a state-of-charge value the device interprets as a fault, stalling the boot sequence before it completes. Charge the battery fully before the first boot — the charge IC applies a conservative limit on new cells, so the first charge cycle may stop short of 100% on the indicator. After one complete charge-discharge cycle, the BMS recalibrates and the boot sequence proceeds normally.
Low battery alarm triggering immediately after a confirmed full charge
This alarm fires when the BMS self-test threshold is set against OEM cell chemistry parameters, and a new replacement cell hasn't yet passed a conditioning cycle. The Virgo's charge IC reads internal resistance during startup — a fresh cell out of storage shows higher impedance than a cycled one, which the device flags as low capacity even at full charge. Run one complete charge-discharge cycle before clinical use. After that cycle the impedance reading drops into the accepted range and the alarm clears at a normal charge level above 14.0V.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Northern
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The Virgo powers off without warning during monitoring — is the new battery causing this?
In the first 10 cycles, a new lithium-ion cell handles the Virgo's load profile less smoothly than a conditioned one. Under clinical load, voltage can momentarily sag below the device's cutoff threshold, triggering an unexpected shutdown. This is not a fault — it resolves as the cell conditions through charge-discharge cycles. Complete at least one full cycle before relying on the battery in a clinical setting, and confirm resting voltage reads above 14.4V before starting a session.
The Virgo sat in storage for several months and won't power on with the old battery — can this new one recover it?
When a lithium-ion cell self-discharges below approximately 10.0V (2.5V per cell), the BMS locks out the charge circuit as a protection measure. Fitting a fresh replacement battery bypasses this entirely — the Virgo will power on normally from the new cell. Remove the depleted original, install this battery, and allow the device to complete its full power-on self-test before use.
The self-test failure flag is showing after I swapped the battery — how do I clear it?
The Virgo's self-test compares BMS data from the installed cell against a stored baseline. A new cell that hasn't completed a learn cycle will produce a mismatch, which the device logs as a self-test failure. This is a BMS calibration state, not a hardware fault. Run one full charge to 16.8V followed by a full discharge under normal device load, then reboot — the BMS stores the new baseline and the flag clears on the next self-test pass.