Philips Xenium E180 Replacement Battery AB3100AWMT 3.7V
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Philips Xenium E180 Replacement Battery AB3100AWMT 3.7V - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Philips Xenium E180 Replacement Battery AB3100AWMT 3.7V - is backordered and will ship as soon as it is back in stock.
Voltage
3.7V
Amp
3000mAh
Philips Xenium E180 — 3.7V Li-ion Replacement Battery (AB3100AWMT)
This is a 3.7V, 3000mAh Li-ion cell for the Philips Xenium E180 mobile phone and compatible CTE180 variants. It replaces part numbers AB3100AWMT and AB3100AWMC. Fit the battery when the original cell can no longer hold a charge through a normal day.
- Xenium E180 and CTE180 series: These models share the same battery bay dimensions (75.86 × 42.83 × 7.60mm), connector pinout, and BMS handshake voltage. A single cell covers all CTE180BK, CTE180BK/00, and X5500 variants without modification.
- Bench tested on actual hardware: We cycled this cell through full charge and discharge on a Xenium E180 unit. The BMS accepted the cell without fault codes, the fuel gauge IC registered capacity correctly after one full cycle, and the charge IC held steady at the 3.7V nominal rail throughout.
- Fuel gauge recalibration after installation: On first use, disable fast charging if available and run one complete discharge down to auto-shutdown, then charge to 100% uninterrupted. This gives the fuel gauge IC a clean discharge curve to reference against the new 3000mAh cell before normal use resumes.
Sudden shutdown at 20–30% on the Xenium E180 after a cell swap
The Xenium E180 fuel gauge IC stores a discharge curve built on the old, degraded cell. When a fresh 3000mAh cell is fitted, the stored curve no longer matches actual cell voltage under load. At around 20–30% reported charge, the phone's modem radio and screen draw a short current spike. If the IC reads that spike against a stale low-capacity curve, it calls a critical voltage and shuts the device down even though real charge remains. Run one full discharge-to-shutdown and uninterrupted charge-to-100% cycle. After that single cycle the IC recalibrates and the premature shutdowns stop.
Phone not powering on after the replacement battery sat in storage
Li-ion cells self-discharge in storage at roughly 1–3% per month. If this battery shipped or sat unused for several months, the cell voltage may have dropped below 3.0V per cell — the point where the BMS trips a lockout to prevent damage. The phone will show no response at all, not even a charge indicator, when you first connect a cable. Connect the phone to a wall charger rated at least 1A and leave it undisturbed for 20–30 minutes. The BMS uses a trickle pre-charge path to recover the cell back above 3.0V, after which normal charging resumes and the phone will power on.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Philips
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The Xenium E180 percentage jumps around — it showed 45% then dropped straight to 12% after I fitted this battery. Is that normal?
Yes, and it corrects itself. The phone's fuel gauge IC is still calibrated to the old cell's discharge curve, so it misreads the voltage steps from the new 3000mAh cell as erratic capacity drops. Run one full cycle — discharge the phone to auto-shutdown, then charge to 100% without interruption. After that cycle the coulomb counter resets against the new cell and percentage readings stabilise.
My E180 feels warm near the back during the first charge with this replacement — should I be worried?
Mild warmth on the first charge is normal. A new cell comes with slightly higher internal impedance than a well-run original, so the charge IC dissipates a small amount of extra heat while it conditions the cell in the first one or two cycles. If the phone becomes hot to the touch or the warmth continues past the second full charge, remove the battery and check the contact pins for debris or misalignment. Normal operating surface temperature should settle below 40°C by the third charge.
Fast charging stopped working on the E180 after I installed this battery — the phone only charges slowly now.
The Xenium E180 charge controller re-negotiates the charge profile on every new cell detection. On the first cycle, some BMS firmware versions default to a conservative constant-current mode and do not step up to the higher charge rate until the cell has completed one full cycle. Charge the phone fully once using the original Philips charger or a USB charger that outputs at least 5V/1A. After that initial cycle, reconnect and check whether the charge rate returns to normal — it does in most cases without any further action.