Schiller Defigard 5000 Compatible Battery 10.8V 4200mAh
This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Schiller Defigard 5000 Compatible Battery 10.8V 4200mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Schiller Defigard 5000 Compatible Battery 10.8V 4200mAh - is backordered and will ship as soon as it is back in stock.
Voltage
10.8V
Amp
4200mAh
Schiller Defigard 5000 Series — 10.8V Li-ion Replacement Battery (3.940100)
This 10.8V 4200mAh Li-ion battery replaces OEM part numbers 3.940100 and 2.200132. It fits the Schiller Defigard 5000, Argus Pro LifeCare 2, DG Touch 7, and APLCII defibrillator platforms. Voltage and cell chemistry match the original specification from the product data.
- Defigard 5000 platform compatibility: These models share a common 10.8V three-cell Li-ion architecture with the same connector format and BMS handshake protocol. The battery management system on each device communicates state-of-charge data back to the unit over the same interface, so one cell pack spans the full model range listed above.
- Bench tested on actual hardware: We ran this cell through charge and discharge cycles on a Defigard 5000 unit. The BMS completed handshake on first insertion, accepted a full charge without fault, and reported state-of-charge accurately to the device display from the first cycle.
- Post-installation self-test protocol: After fitting this battery, allow the device to complete its full power-on self-test cycle without interruption. The Defigard 5000 runs a BMS verification routine at startup — cutting power during this sequence triggers a false battery fault that persists until the next clean reboot.
Defigard 5000 charge indicator stalling below 100% on first charge
On the first charge cycle, the Defigard 5000 charge IC applies a conservative current limit while it characterises the new cell. This causes the indicator to plateau at 90–95% for an extended period before completing. It is not a fault with the battery or the charger. Allow the charge cycle to run to completion without removing the battery. After one full charge-discharge cycle, the charge IC recalibrates and subsequent charges reach 100% at the expected rate.
Device will not power on after battery sat unused in storage
Li-ion cells self-discharge during storage. If this battery shipped or sat on a shelf for several weeks, the resting voltage may have dropped below the Defigard 5000's BMS recovery threshold — typically around 9V for a 10.8V three-cell pack. The device will not boot from this state because the BMS interprets sub-threshold voltage as a damaged or absent cell. Connect the battery to a compatible charger and leave it for a minimum 30-minute pre-charge before attempting to power on the device. Once voltage recovers above the recovery threshold, the BMS clears the lockout and normal boot proceeds.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Schiller
- Manufacturer: CS
- Series: Standard
- Color: Grey
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The Defigard 5000 shows a low battery alarm immediately after I fit a fully charged replacement — what's happening?
The device BMS compares the incoming cell's state-of-charge profile against a threshold calibrated to a conditioned OEM cell. A new battery on its first cycle hasn't completed the BMS learn sequence, so the reported state-of-charge reads lower than the actual charge level. Run one full charge-discharge cycle before clinical use — after that cycle, the BMS recalibrates to the new cell and the alarm clears.
The Defigard 5000 shut off unexpectedly mid-use after the battery swap — is this a faulty cell?
New Li-ion cells have slightly higher internal resistance in their first 10 cycles. The Defigard 5000's load profile during defibrillation charge cycles draws hard on the pack, and the BMS can trip on a transient voltage sag if the cell hasn't been conditioned yet. This is not a faulty cell — it is the BMS protecting against what it reads as an undervoltage event. Complete three full charge-discharge cycles before deploying the device clinically, which lowers internal resistance and brings the cell within the BMS's expected voltage window.
The Defigard 5000 is failing its power-on self-test after the battery replacement — how do I clear it?
The self-test failure is almost always a BMS learn cycle issue, not a hardware fault. The device runs a battery verification routine at boot, and if the new cell hasn't completed one full charge-discharge cycle, the BMS returns a result that fails the self-test threshold. Charge the battery to full, run the device through one complete discharge, then recharge to 100% and reboot. If the self-test passes after that cycle, the battery is functioning correctly and the device is ready for clinical use.