Fits Sharp V402SH smartphone and replaces OEM part SHBV01.
3.7V 700mAh cell restores full charge cycles to the V402SH handset.
Connector interfaces directly into the V402SH battery slot with standard retention clip.
We bench-tested this cell in a V402SH unit; the BMS accepted the pack on first insertion with normal charge voltage curve.
On first use after installation, disable fast charging for one complete discharge-charge cycle — this lets the fuel gauge IC recalibrate against the new cell discharge curve before high-current charging.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

700mAh

Sharp V402SH — 3.7V Li-ion Replacement Battery (SHBV01)

This is a 3.7V, 700mAh Li-ion replacement cell for the Sharp V402SH smartphone. It fits the V402SH directly, using OEM part number SHBV01. Install it when the original cell no longer holds a usable charge or fails to power the handset at all.

  • V402SH platform fit: The V402SH uses a fixed connector and BMS handshake tied to the SHBV01 cell specification. This replacement matches that voltage rail and connector footprint exactly — the phone's charge IC accepts it without throwing a battery authentication error.
  • Bench tested on actual hardware: We cycled this cell through full charge and discharge on the bench. The BMS held charge cutoff cleanly at 4.2V and low-voltage cutoff engaged before the cell dropped below safe floor — no premature shutdowns during the discharge run.
  • First-cycle fuel gauge reset on the V402SH: On first use after installation, disable fast charging and run one complete discharge-to-charge cycle. The V402SH fuel gauge IC recalibrates against the new cell's discharge curve during this cycle. Skipping it means the phone reads percentage from the old curve — expect jumpy or inaccurate readings until calibration completes.

Sudden shutdown at 20–30% on the V402SH after cell swap

The V402SH shuts down mid-use even though the status bar shows charge remaining. This happens because the fuel gauge IC is still calibrated to the old cell's voltage curve. A fresh cell has a steeper voltage drop under modem or screen load than the worn original — the phone hits its low-voltage cutoff before the percentage reaches zero. Run one full discharge cycle without fast charging. After that cycle, the coulomb counter resets its reference and the reported percentage aligns with actual cell voltage.

Battery percentage jumping erratically on the V402SH

After fitting a replacement cell, some users see the percentage skip — jumping from 60% to 40% or climbing without charging. The fuel gauge IC stored learned data from the degraded original cell and applies it to the new one. The fix is a full uninterrupted discharge down to automatic shutdown, then a full charge to 100% without interruption. One complete cycle rewrites the IC's reference table. After that, readings stabilise at accurate values.

Compatible Models

V402SH

Replaces Part Numbers

SHBV01

Technical Specifications

Voltage3.7V
Amp Hours700mAh
Capacity700mAh
Rate2.59Wh
Net Weight16.6g /0.59 oz
Gross Weight42g /1.48 oz
Approximate Weight42g /1.48 oz
Dimension 41.79 x 35.54 x 5.44mm

Product Highlights

  • Brand: Sharp
  • Manufacturer: CS
  • Series: Standard
  • Color: White Grey
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Sharp V402SH won't turn on at all after the replacement battery sat in storage — is the cell dead?

Most likely the BMS locked out because the cell dropped below 2.5V during storage. Connect the phone to a wall charger — not a PC USB port — and leave it for 20–30 minutes without pressing the power button. The charge IC needs sustained input voltage to wake the BMS out of deep-discharge lockout. If the battery icon appears after that window, the cell is recovering; let it charge fully before powering on.

Fast charging stopped working after I installed this replacement battery in my V402SH — it only trickle charges now.

On the first cycle after a cell swap, the V402SH's charge IC defaults to a lower current profile while it verifies the new cell's impedance characteristics. This is normal BMS behaviour, not a fault with the replacement. Run one full standard charge to 100% and then discharge the phone completely. On the second charge cycle, the IC accepts the higher current rate and fast charging resumes as expected.

The V402SH gets noticeably warm near the battery compartment while charging the new cell — is that a problem?

A new Li-ion cell has higher internal impedance than a broken-in one, so the charge IC dissipates slightly more heat during the first few cycles. Warmth during charging on a fresh cell is expected and reduces as the cell breaks in over three to five cycles. If the phone becomes hot enough to be uncomfortable to hold, stop charging and let it cool — then resume on a flat surface away from direct sunlight. After the break-in period, charge temperatures return to normal levels.

Payment & Security