Fits Streamer YH08-W1690 16W emergency lighting unit, replaces OEM part KRH33/62.
9.6V, 5000mAh Ni-MH chemistry delivers full capacity for standard 16W fixture duration tests without voltage sag.
Connector slides into vertical slot with single locking tab on unit base — no keying required.
Bench testing showed stable voltage ramp on first charge with no BMS fault codes or premature cutoff.
Run a full manual test cycle within 24 hours of installation by holding the test button for rated duration — this conditions the cell and allows the charge controller to register new capacity before compliance testing.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

9.6V

Amp

5000mAh

Streamer YH08-W1690 16W — 9.6V Ni-MH Replacement Battery (KRH33/62)

This is a 9.6V, 5000mAh Ni-MH replacement battery for the Streamer YH08-W1690 16W emergency lighting unit. It slots directly into the fitting and restores the backup illumination function lost when the original cell degrades. Confirm your fitting's part label reads KRH33/62 before ordering.

  • YH08-W1690 16W platform fit: This cell matches the voltage rail, physical dimensions, and connector orientation the YH08-W1690 charge controller expects. A mismatched voltage forces the controller into a continuous trickle state, which damages the new cell within weeks.
  • Bench tested on actual hardware: We ran this cell through a simulated mains-failure cycle. The charge controller accepted the new cell, transitioned from charge to float, and the lamp activated cleanly at the correct voltage threshold under full 16W draw.
  • First test-cycle conditioning: Within 24 hours of installation, hold the test button for the full rated duration. This lets the cell accept a load cycle and gives the charge controller a baseline reading before any compliance test is logged against the fitting.

Charge indicator staying red after new battery installation

Ni-MH cells lose charge during storage. If the cell voltage drops far enough, the YH08-W1690 charge controller may not recognise it as a valid cell and holds the red fault indicator rather than entering normal charge mode. Leave the fitting connected to mains for a full 24-hour charge cycle before drawing any conclusions. If the indicator is still red after 24 hours, check the connector seating — a partially seated connector causes the same symptom. A fully charged and accepted cell should read approximately 11.0V across the terminals before the controller switches to float.

Emergency light dims partway through a duration test after replacement

A new cell that has not completed a full conditioning cycle will show an apparent capacity shortfall — the lamp dims or cuts before the rated duration ends. This happens because the charge controller has not yet established the cell's full charge ceiling. Run one complete manual test cycle, then allow a full 24-hour recharge before the next test. After that cycle, the cell should sustain the 16W lamp load across the full rated duration without dimming.

Compatible Models

YH08-W1690 16W

Replaces Part Numbers

KRH33/62

Technical Specifications

Voltage9.6V
Amp Hours5000mAh
Capacity5000mAh
Rate48Wh
Net Weight880g /31.04 oz
Gross Weight1190g /41.98 oz
Approximate Weight1190g /41.98 oz
Dimension 279.00 x 65.60 x 33.80mm

Product Highlights

  • Brand: Streamer
  • Manufacturer: CS
  • Series: Standard
  • Color: White
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Streamer YH08-W1690 failed its compliance duration test the day after I fitted the new battery — did I get a faulty cell?

Almost certainly not. A fresh Ni-MH cell needs one full discharge-recharge cycle before it can deliver its rated capacity. The charge controller in the YH08-W1690 hasn't yet established the cell's charge ceiling, so the first test often cuts short. Run the manual test button for the full rated duration, then leave the fitting on mains for a full 24 hours, and retest — the cell should pass.

The fitting's LED is still showing a fault after I installed the replacement battery and waited overnight — what's wrong?

Some YH08-W1690 fittings latch the fault LED in hardware and won't clear it automatically after a battery swap. First confirm the connector is fully seated — a partial connection reads the same as a missing cell. If the connection is good and the cell terminal voltage is above 10.8V after a 24-hour charge, locate the reset pinhole or press-and-hold sequence on the fitting's control board to manually clear the fault state.

The original battery in my YH08-W1690 has swollen and is wedged in the housing — is that a charging fault I need to fix before fitting the new cell?

Swelling in Ni-MH emergency light cells is caused by years of continuous trickle charge at elevated temperature inside a sealed fitting — it is a known long-term failure mode, not a one-off fault. Before fitting the replacement, check that the charge controller board shows no signs of heat damage or burnt components around the charge resistors. If the board looks clean, the new cell can go straight in. If the board shows burn marks, replace the fitting before installing a new cell.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.