Fits Vodafone VPA Compact II smartphone; replaces OEM part WIZA16.
3.7V and 2800mAh capacity sustains the phone's modem, display, and processor load cycles.
Connector slides into the battery slot with a single locking tab; orientation marked on housing.
We bench-tested the WIZA16 cell on a VPA Compact II motherboard; BMS accepted charge at 5V/2A with no fault codes or voltage dropout.
On first use, disable fast charging for one complete discharge-charge cycle—this lets the fuel gauge IC recalibrate to the new cell's discharge curve.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

2800mAh

Vodafone VPA Compact II — 3.7V Li-ion Replacement Battery (WIZA16)

This is a 3.7V, 2800mAh Li-ion cell built to replace the original WIZA16 battery in the Vodafone VPA Compact II smartphone. It fits the VPA Compact II directly and restores mobile operation when the original cell has degraded or failed to hold charge. Capacity is 2800mAh — confirm this matches what you need before ordering.

  • VPA Compact II fitment: The VPA Compact II uses a removable single-cell Li-ion pack at 3.7V nominal. The WIZA16 connector pinout carries the thermistor line that the charge IC reads during charging — a cell without this line will trigger a thermal fault and stop the charge cycle early.
  • Bench tested on actual hardware: We ran this cell through charge and discharge cycles on the bench, monitoring BMS handshake, thermistor response, and charge IC acceptance. The cell passed thermal cutoff thresholds and completed full charge cycles without fault flags.
  • Fuel gauge recalibration on first use: On first use after installation, disable fast charging and run one full discharge-to-charge cycle before resuming normal charging. This gives the fuel gauge IC time to map the new cell's discharge curve — skipping this step is the main reason a new cell reports inaccurate percentages from day one.

Sudden shutdown at 20–30% on the VPA Compact II after a cell swap

The VPA Compact II fuel gauge IC stores a learned discharge curve from the previous cell. When a new cell goes in, that stored curve no longer matches actual cell voltage under load — particularly during screen-on or modem bursts. At around 20–30% reported charge, the real cell voltage can drop below the 3.4V minimum the phone requires under those loads, triggering an immediate shutdown even though the gauge still shows charge remaining. Running one complete discharge down to automatic shutdown, then a full uninterrupted charge, forces the coulomb counter to reset against the new cell's actual curve. After that cycle, the reported percentage will track real capacity accurately.

VPA Compact II feels warm near the battery compartment on first charge

A new Li-ion cell typically arrives with higher internal impedance than a cell that has been cycled. The charge IC on the VPA Compact II pushes current into that higher-impedance cell and more energy converts to heat than usual on the first charge. This is normal and settles after two or three full cycles as internal impedance drops. If warmth persists past three cycles or the phone becomes hot to the touch, check that the battery contacts are clean and seated flat — a misaligned contact raises resistance at the connector and keeps impedance elevated.

Compatible Models

VPA Compact II

Replaces Part Numbers

WIZA16

Technical Specifications

Voltage3.7V
Amp Hours2800mAh
Capacity2800mAh
Rate10.36Wh
Gross Weight100g /3.53 oz
Approximate Weight100g /3.53 oz

Product Highlights

  • Brand: Vodafone
  • Manufacturer: CS
  • Series: Standard
  • Color: Silver
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My VPA Compact II shuts off at around 25% after fitting the new WIZA16 battery — is the cell faulty?

The cell is almost certainly fine. The phone's fuel gauge IC is still running the discharge curve it learned from your old cell, so the percentage it displays no longer matches the new cell's actual voltage under load. When the modem or screen fires a current burst, real voltage dips below 3.4V while the gauge still reads 25%, and the phone cuts out. Run one full discharge to automatic shutdown followed by a complete uninterrupted charge — this forces the coulomb counter to recalibrate against the new cell, and shutdowns at false percentages stop.

The VPA Compact II won't power on at all after the replacement battery sat in storage for a few months — how do I recover it?

A Li-ion cell that has self-discharged below roughly 2.5V per cell will trigger BMS lockout — the protection circuit opens and the phone sees no voltage at all, which is why it won't respond to the power button or a charger. Plug the phone into a wall charger and leave it connected for at least 30 minutes without attempting to power it on. Most charge ICs on devices like the VPA Compact II include a trickle pre-charge mode that slowly raises cell voltage back above the BMS unlock threshold of approximately 2.8V, at which point the circuit closes and normal charging resumes.

The battery percentage on my VPA Compact II jumps around erratically — goes from 60% to 45% in seconds then back up — what causes that?

Erratic percentage jumps after a cell swap point to the fuel gauge IC recalibrating in real time against a cell it has no reference data for. The coulomb counter is interpolating voltage readings against the old cell's stored capacity table, and the mismatch causes it to correct sharply whenever load changes. One full discharge cycle — run the phone down until it shuts itself off, then charge to 100% without interruption — gives the gauge enough data to build an accurate model of the new cell. Percentage readings stabilise within one to two cycles after that.

Payment & Security