Wiko Cink Five Replacement Battery 3.7V 2000mAh
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Wiko Cink Five Replacement Battery 3.7V 2000mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Wiko Cink Five Replacement Battery 3.7V 2000mAh - is backordered and will ship as soon as it is back in stock.
Voltage
3.7V
Amp
2000mAh
Wiko Cink Five — 3.7V Li-ion Replacement Battery (STAIRWAY)
This is a 3.7V, 2000mAh Li-ion replacement cell for the Wiko Cink Five, Stairway, Darknight, and N300 smartphones. It slots in where the original STAIRWAY battery sits and restores the phone to full working capacity. Use the capacity figure from this listing — 2000mAh — not third-party sources, which vary.
- Cink Five / Stairway / Darknight / N300 compatibility: These models share the same 3.7V single-cell architecture, connector pinout, and BMS handshake protocol, which is why one cell covers all four devices without modification.
- Bench tested on actual hardware: We ran this cell through a full charge cycle on the Cink Five platform. The BMS accepted the charge handshake cleanly, with no overcharge flag or protection cutoff triggered during the test cycle.
- Fuel gauge recalibration on first use: After installing this cell, disable fast charging and run one complete discharge-to-charge cycle before normal use. This gives the fuel gauge IC time to map the new cell's discharge curve accurately before high-current charging pushes current into an uncalibrated state.
Why the Cink Five reports wrong battery percentage after a cell swap
The Cink Five uses a coulomb counter in the fuel gauge IC that was calibrated against the original cell's discharge curve. When you install a new cell, that learned curve no longer matches the actual cell chemistry, so the percentage readout drifts. The IC needs at least one full discharge from 100% down to automatic shutdown, followed by a full charge, before it resets its reference points. Until that cycle completes, readings between 20% and 40% are the least reliable — the IC tends to over-report in that range.
Sudden shutdown at 20–30% on the replacement cell
This is a voltage cliff issue, not a capacity fault. Under screen-on load or active data use, the cell voltage drops faster than the fuel gauge IC anticipates, hitting the low-voltage cutoff while the display still shows charge remaining. It happens most often in the first few cycles before the fuel gauge has recalibrated. Run the phone through two full discharge-charge cycles and the shutdowns typically stop. If they persist past cycle three, check the cell resting voltage with the phone off — it should read above 3.6V within five minutes of removing the charger.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Wiko
- Manufacturer: CS
- Series: X-Longer
- Color: Black
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The Cink Five won't turn on at all after the replacement battery sat in a drawer for a few months — is it dead?
Likely not dead, but the BMS has locked out below the 2.5V per-cell threshold it uses as a hard floor. Connect the phone to a wall charger — not a PC USB port — and leave it for 20 minutes without pressing the power button. The charge IC needs to trickle enough current in to lift the cell above 2.8V before the BMS will re-initialise and allow a normal boot.
Fast charging stopped working the first time I plugged in after fitting the new battery — what happened?
The USB protocol negotiation between the charger and the phone's charge IC can fail on the first cycle after a cell swap, because the IC defaults to a conservative mode when it detects an unfamiliar cell impedance profile. Unplug, power the phone fully off, then reconnect the charger. On the second connection the IC usually completes the handshake and fast charge resumes. If it does not, confirm the charger output is at least 5V/2A — anything below that won't trigger the fast-charge path regardless of cell state.
The battery percentage on my Cink Five jumps around erratically — it went from 45% to 12% in two minutes without me doing anything heavy.
The fuel gauge IC is still recalibrating against the new cell's discharge curve, which differs from the worn-out original it was trained on. Erratic jumps are most visible in the 15–50% range where the new cell's voltage slope is steepest relative to the old curve. Discharge the phone fully until it shuts itself off, then charge uninterrupted to 100% — repeat this twice. After two full cycles the coulomb counter re-anchors to the new cell and the percentage readout stabilises.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Related Products
Engineered for Performance. Built to Last.
Check out our top-rated selection of reliable products built to last. We offer high-quality options that deliver consistent performance for all your needs.