BLU C5 Replacement Battery 3.7V 2500mAh C775840200L
This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
BLU C5 Replacement Battery 3.7V 2500mAh C775840200L - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
BLU C5 Replacement Battery 3.7V 2500mAh C775840200L - is backordered and will ship as soon as it is back in stock.
Voltage
3.7V
Amp
2500mAh
BLU C5 / C010Q — 3.7V Li-Polymer Replacement Battery (C775840200L)
This 3.7V, 2500mAh Li-Polymer cell replaces OEM part C775840200L in the BLU C5 and C010Q smartphones. It matches the original pack's voltage rail, physical footprint (76.90 × 58.50 × 4.50mm), and connector orientation. Capacity is rated at 9.25Wh — identical to the factory specification.
- C5 and C010Q platform fit: Both models share the same battery bay dimensions, 3.7V nominal rail, and BMS handshake protocol — one cell covers both variants without modification.
- Bench tested on actual hardware: We cycled this cell through full charge and discharge on a BLU C5 unit. The BMS accepted the pack without fault flags, and the charge IC completed the constant-current to constant-voltage transition cleanly at 4.2V.
- Fuel gauge recalibration on first use: On first use after installation, disable fast charging and run one complete discharge-charge cycle at standard rate. This lets the fuel gauge IC map the new cell's discharge curve before the OS starts reporting accurate percentages.
Sudden shutdown at 20–30% on the BLU C5 after a cell swap
This happens because the fuel gauge IC is still using the discharge curve it built around the old, degraded cell. The new cell has a steeper voltage drop under modem and screen load than the IC expects, so it misreads remaining capacity. When the phone pulls current for a data burst or screen wake, voltage dips below the hardware cutoff threshold — around 3.2V — before the gauge catches up. One full discharge-charge cycle at standard current forces the coulomb counter to rebuild its reference curve against the new cell.
BLU C5 won't power on after sitting in storage — BMS lockout recovery
Li-Polymer cells that drop below approximately 2.5V per cell trigger a protective BMS lockout to prevent damage. If the phone shows no response and won't charge via USB, the BMS has likely tripped. Connect the phone to a wall charger — not a PC port — and leave it for 15–20 minutes without pressing any buttons. The charge IC delivers a trickle current that nudges cell voltage above the BMS re-enable threshold, typically 2.9V, at which point normal charging resumes and the phone will power on.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: BLU
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Li-Polymer
- Battery Type: Li-Polymer
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My BLU C5 shuts off randomly at around 25% battery — is the new cell faulty?
Almost certainly not a faulty cell. The fuel gauge IC in the C5 calibrated its discharge curve to the old battery, and the new cell's voltage behaviour doesn't match that stored profile yet. Under high-draw moments — mobile data, screen-on bursts — voltage sags faster than the gauge predicts, triggering a hardware cutoff before the displayed percentage reaches zero. Run one full discharge down to automatic shutdown, then charge uninterrupted to 100% at standard rate, and the coulomb counter will recalibrate against the new cell.
Fast charging stopped working after I fitted the replacement battery — what's happening?
On the first cycle after a cell swap, some charge ICs default to standard current until they confirm the new pack's BMS is responding correctly. The C5 checks impedance and BMS acknowledgement before enabling higher charge rates, and a brand-new cell with slightly higher internal impedance can cause the IC to stay in trickle or standard mode. Complete one full charge at standard rate without interruption, then reconnect — fast charging typically re-enables automatically once the IC has logged a clean charge cycle against the new cell's profile.
The battery percentage on my BLU C5 keeps jumping around erratically after replacement — how do I fix it?
Erratic percentage readings after a cell swap are a fuel gauge IC recalibration issue, not a hardware fault. The IC's stored charge curve no longer matches the new cell, so its state-of-charge estimates drift. Drain the phone fully until it shuts itself off, then charge it in one uninterrupted session to 100%. That single complete cycle gives the coulomb counter enough data to rebuild an accurate reference curve, and percentage reporting stabilises from that point.