Datalogic BY-01 Barcode Scanner Replacement Battery 3.7V 3200mAh
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Datalogic BY-01 Barcode Scanner Replacement Battery 3.7V 3200mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Datalogic BY-01 Barcode Scanner Replacement Battery 3.7V 3200mAh - is backordered and will ship as soon as it is back in stock.
Voltage
3.7V
Amp
3200mAh
Datalogic BY-01 — 3.7V Li-ion Replacement Battery (BY-01 / 700311800)
This 3.7V, 3200mAh Li-ion battery fits the Datalogic BY-01 handheld barcode scanner. It replaces OEM parts BY-01 and 700311800. The BY-01 scanner is a compact unit used across retail, warehousing, and logistics pick-and-pack operations.
- BY-01 scanner platform fit: The BY-01 battery uses a 3.7V single-cell architecture matched to the scanner's imaging and wireless communication circuits. The connector pinout and BMS communication protocol align directly with the OEM charge management system inside the device.
- Bench tested on actual hardware: We ran this pack through charge cycles on the BY-01 and monitored BMS handshake, cutoff thresholds, and charge acceptance. The protection circuit triggered correctly at both high-current scan bursts and low-voltage cutoff, consistent with OEM behaviour.
- First-shift prep for pick-and-pack use: After installing, seat the scanner in its cradle for a full charge cycle before putting it on the floor. Scan trigger inrush current is highest when the cell is near minimum charge, and a pre-charged pack prevents false BMS trips when your team starts their first shift.
Cradle showing a charging error on a new pack
The BY-01 cradle reads the battery's charge state through contact pins on the base of the scanner. If those contacts are dirty or slightly misaligned, the dock reports a fault even when the pack itself is fine. Wipe the gold contacts on both the battery and the cradle with a dry cloth, then reseat the scanner firmly until it clicks. If the error clears within 60 seconds, contact resistance was the cause — not a faulty cell. The cradle should register a normal charge state above 3.0V at rest.
Scanner losing wireless connection during rapid scan bursts
During a fast scanning sequence, the BY-01 draws simultaneously from the imager, processor, and wireless radio. If the cell voltage sags under that combined load, the radio drops its connection before the scanner fully powers off — it looks like a wireless fault, but it is a power delivery issue. A fully charged pack handles the inrush; a partially depleted or degraded cell cannot sustain the voltage rail. Check the open-circuit voltage with a multimeter — anything below 3.5V under no load indicates the cell needs charging or has degraded past useful capacity.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Datalogic
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My BY-01 scanner stopped reading barcodes right after I swapped the battery — what's wrong?
The imager needs a minimum supply voltage to fire the laser or LED array. If the replacement pack shipped partially discharged, the cell voltage may be too low to power the imaging module even though the scanner appears to be on. Place the scanner in the cradle and charge it fully before use. Once the pack reaches 4.1V–4.2V, the imager should return to normal operation.
The scanner feels warm after a long shift — is that a battery problem or a device problem?
Sustained scanning combined with continuous wireless polling generates heat inside the BY-01's compact housing. The battery itself will be slightly warm under that combined draw, which is normal. What is not normal is the scanner becoming too hot to hold comfortably — that points to a cell that has degraded internally and is dissipating energy as heat rather than delivering it as usable current. If warmth is excessive, check the pack's resting voltage after a full charge; a degraded cell will sit below 4.0V at full charge termination.
The new battery seems to run out faster than expected on high-volume scanning days — what's causing that?
Scan burst frequency and wireless polling both draw from the same cell simultaneously. On a high-volume shift, the combined draw is significantly higher than light or intermittent use, and actual endurance will be shorter than on a quiet shift. That said, if endurance dropped sharply from the very first cycle, check that the pack completed a full initial charge in the cradle before use — an incomplete first charge reduces available capacity until the cell is fully cycled. Run one complete charge-discharge-charge cycle and compare shift performance before drawing conclusions about the pack.