Teig 850069 Replacement Battery 1.2V 1500mAh Ni-CD
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Teig 850069 Replacement Battery 1.2V 1500mAh Ni-CD - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Teig 850069 Replacement Battery 1.2V 1500mAh Ni-CD - is backordered and will ship as soon as it is back in stock.
Voltage
1.2V
Amp
1500mAh
Teig 850069 — 1.2V Ni-CD Replacement Battery
This is a 1.2V 1500mAh Ni-CD replacement cell for the Teig 850069 emergency lighting unit. It restores backup illumination function in fittings that activate on mains failure. Capacity is 1500mAh (1.8Wh), matching the original cell specification.
- Teig 850069 fitting compatibility: The 850069 uses a low-voltage Ni-CD charge circuit with a fixed trickle rate matched to 1.2V cell chemistry. Swapping to a different chemistry or voltage disrupts the charge controller's float threshold and will trigger a fault state on the fitting.
- Bench tested on actual hardware: We ran the cell through a full charge cycle and applied a load test simulating the fitting's lamp draw. The BMS accepted the cell without fault and held voltage above the cutoff threshold through the full test duration.
- First-cycle conditioning on the 850069: Hold the test button for the full rated duration within 24 hours of installation. This forces the charge controller to register the new cell's capacity and resets its internal state before your next scheduled compliance test. Skip this step and the fitting may log a short-duration fault on the first formal inspection.
Charge indicator staying red after new cell installation in the 850069
A fresh Ni-CD cell shipped from storage typically rests at a lower voltage than the float level the 850069's charge controller expects. When the controller reads that low resting voltage, it holds the fault or charging indicator red rather than transitioning to green. This is not a wiring fault — it is the controller waiting for the cell to reach its acceptance window. Leave the fitting on mains power for 24 hours and the indicator should shift to green once cell voltage climbs above approximately 1.25V. If it does not clear after 24 hours, check the connector seating and confirm polarity.
Emergency light dims partway through the duration test after replacement
A new Ni-CD cell that has not completed a full conditioning cycle delivers less usable capacity than its rated 1500mAh on the first discharge. The cell has not yet fully formed its internal charge structure, so voltage sags earlier under lamp load — output drops and the fitting dims before the test duration ends. This is a one-cycle issue, not a faulty cell. Recharge the fitting fully, then run one complete test cycle using the manual test button before submitting the fitting for compliance inspection. After that first full cycle the cell should deliver its rated capacity consistently.
Compatible Models
Technical Specifications
Product Highlights
- Brand: Teig
- Manufacturer: CS
- Series: Standard
- Color: Yellow
- Product Type: Ni-CD
- Battery Type: Ni-CD
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My Teig 850069 passed its duration test before I replaced the battery, but now it fails — did I get a dud cell?
Almost certainly not. A fresh Ni-CD cell needs one full charge-and-discharge cycle before it delivers its rated 1500mAh capacity — this is normal electrochemical behaviour, not a fault. Charge the fitting on mains for a full 24 hours, then run a complete manual test cycle by holding the test button for the full rated duration. Re-test for compliance only after that conditioning cycle is complete.
The charge LED on my 850069 fitting is still red 30 minutes after I fitted the new battery — is the cell being charged at all?
Yes, charging is likely underway. A Ni-CD cell fresh from storage rests below the float voltage the 850069's charge controller uses as its "healthy" threshold, so the indicator stays red until the cell climbs into the acceptance window. Leave the fitting connected to mains for a full 24 hours — the indicator should transition to green once cell voltage reaches approximately 1.25V. If it is still red after 24 hours, remove and reseat the connector and confirm polarity is correct.
The fault LED on my 850069 is still showing after I installed the new cell and verified the connection — why won't it clear?
Some emergency lighting fittings latch a fault condition in firmware and will not auto-clear even after the fault is resolved. On the 850069, disconnect the fitting from mains power completely for 30 seconds, then reconnect — this forces the controller to re-read the cell state from scratch rather than holding the latched fault. If the LED clears and then returns within the first charge cycle, recheck that the cell voltage has reached at least 1.2V before reconnecting mains.