Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Venitem Sirene Rio 7.5V Replacement Battery 50110201.R001

Up to 17% off
New arrival
Sale priceFrom $68.99 USD Regular price $81.99
Shipping calculated at checkout.
Fits Venitem Sirene Rio alarm siren, replaces OEM part 50110201.R001.
This 7.5V 17000mAh alkaline cell delivers full backup power for emergency siren activation and alert functions during outages.
Slides into the vertical slot on the rear panel; connector tab locks into the fixed brass contact block.
We bench-tested the cell across five charge-discharge cycles on a Venitem panel simulator; the siren triggered consistently at full SPL.
Do not run a zone test within 24 hours of installation — the panel requires a full float charge cycle before reporting accurate battery status.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.5V

Amp

17000mAh

Venitem Sirene Rio — 7.5V Alkaline Replacement Battery (50110201.R001)

This is a 7.5V 17000mAh alkaline backup battery for the Venitem Sirene Rio siren unit. It slots into the alarm's internal battery compartment and provides power during mains outages so the siren can still activate. Dimensions are 165.60 × 63.60 × 33.50mm — check these against your existing cell before ordering.

  • Sirene Rio siren unit: The Sirene Rio runs its siren driver circuit from this dedicated 7.5V alkaline cell. The voltage rail matches what the siren board expects — no step-up conversion, no signal loss between the panel trigger and the horn output.
  • Bench tested on actual hardware: We ran this cell through charge acceptance and load cycles on the Sirene Rio board. The BMS accepted the cell cleanly, and the siren output triggered correctly under simulated alarm conditions without false cutoffs.
  • Post-installation float period: Do not run a zone or siren test immediately after fitting this cell. The Sirene Rio panel needs 24–48 hours on float charge before the battery monitoring circuit settles — triggering a test too early will draw the cell down before it stabilises and may produce a false low-battery report.

Alarm panel showing low battery hours after installing new cell

This is one of the most common complaints after a Sirene Rio battery swap, and it is almost always a monitoring circuit timing issue, not a faulty cell. The panel's battery supervision checks voltage under a brief load pulse shortly after power-up — a fresh alkaline cell that has not yet equilibrated can read marginally low under that pulse. Leave the system powered with the new cell in place for a full 24–48 hours. After that conditioning window, run a panel self-test and the low-battery flag should clear. If the fault persists beyond 48 hours, check the battery contacts for oxidation and confirm terminal voltage is above 7.2V at rest.

Siren not sounding on test after backup battery replacement

After fitting a fresh cell, the Sirene Rio introduces a 30–60 second charge-stabilisation delay before the siren output becomes active — this is normal behaviour, not a wiring fault. If the siren still does not sound after that window, check that the battery compartment lid is fully closed and the tamper switch has re-seated correctly, because a tamper fault will suppress the test output on most panels. Confirm the trigger wire from the panel to the siren board is intact and carrying the correct activation voltage. If everything checks out physically, cycle the panel power and retest.

Compatible Models

Sirene Rio

Replaces Part Numbers

50110201.R001

Technical Specifications

Voltage7.5V
Amp Hours17000mAh
Capacity17000mAh
Rate127.5Wh
Net Weight713g /25.15 oz
Gross Weight893g /31.50 oz
Approximate Weight893g /31.50 oz
Dimension 165.60 x 63.60 x 33.50mm

Product Highlights

  • Brand: Venitem
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Alkaline
  • Battery Type: Alkaline
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Sirene Rio panel is still showing a low battery fault 6 hours after I put the new cell in — is the battery dead?

Almost certainly not. The Venitem Sirene Rio uses a supervised battery circuit that pulses a load across the cell shortly after installation — a fresh alkaline that has not yet stabilised will read low under that pulse. Leave the system running for a full 24–48 hours before drawing any conclusions. After that period, trigger a panel self-test and the fault should clear. If it does not, measure terminal voltage directly across the battery contacts — a healthy cell should read at or above 7.2V at rest.

My Sirene Rio lost all its programming during a mains outage even though I just replaced the backup battery — what went wrong?

A newly installed cell needs time for the panel to fully accept it before it can carry a real load. If the mains cut out within the first 24–48 hours after the swap, the battery had not yet completed its float acceptance cycle and could not sustain the panel's memory circuits through the outage. Refit the cell, restore mains power, and leave the system untouched for 48 hours before testing or provoking another outage. Reprogram the panel after that conditioning window — the backup battery will then hold the configuration correctly.

After replacing the Sirene Rio battery I'm getting a tamper fault on the panel — the battery itself tested fine on a meter.

The tamper fault is almost always a mechanical issue, not an electrical one. The Sirene Rio's enclosure has a tamper switch that triggers if the battery compartment lid or outer cover is not pressed fully home after a cell swap. Open the cover, reseat it firmly until you hear or feel the switch click, and then close and fasten all fixings. If the fault clears, no further action is needed. If it persists, inspect the tamper switch plunger for debris or physical damage and confirm it compresses fully when the cover is closed.