Fits Archos AC101OX4G and OXYGEN 4G tablets, replacing OEM battery part numbers 3097138 and 29100145.
3.7V, 4400mAh Li-Polymer cell restores full capacity to the 10-inch display and WiFi radio on this Android tablet.
Connector solders directly to the tablet motherboard; polarity marked on the cell body and PCB prevents reverse installation.
We bench-tested the BMS charge profile under display and WiFi load; the cell accepted full 5V input without cutoff or thermal drift.
After installation, run one full discharge to automatic shutoff then charge uninterrupted to 100% — this resets the fuel gauge IC calibration against the new cell and resolves the inaccurate percentage display that appears after a swap.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

4400mAh

Archos AC101OX4G / OXYGEN 4G — 3.7V Li-Polymer Replacement Battery (3097138)

This is a 3.7V, 4400mAh Li-Polymer battery for the Archos AC101OX4G and OXYGEN 4G 10-inch Android tablets. It replaces OEM part numbers 3097138 and 29100145. When the original cell degrades and the tablet no longer holds a charge, this unit restores full power capacity.

  • AC101OX4G and OXYGEN 4G compatibility: Both models run the same 3.7V power rail and use the same flex connector and BMS handshake, so a single cell covers both variants without modification.
  • Bench tested on actual hardware: We cycled this battery through charge and discharge on the AC101OX4G platform. The BMS accepted charge normally, voltage held steady across the display and WiFi load, and no false-low cutoff events occurred.
  • Fuel gauge recalibration after swap: After fitting this battery, run one full discharge to automatic shutoff, then charge uninterrupted to 100%. This resets the fuel gauge IC against the new cell's actual capacity curve and eliminates the inaccurate percentage reading that commonly appears after a battery swap.

Why the AC101OX4G shuts down at 15–25% remaining

The tablet's charge IC calibrated its low-voltage cutoff point against the old, degraded cell. With a fresh cell installed, the voltage curve is steeper in the lower range, and the IC triggers shutdown earlier than the displayed percentage suggests. The fix is a full recalibration cycle: discharge the tablet to automatic shutoff, then charge without interruption to 100%. After one complete cycle, the fuel gauge IC maps its cutoff thresholds to the new cell's actual discharge curve and shutdown at false-high percentages stops.

Fast charging unavailable after battery replacement on the OXYGEN 4G

Some users find the fast charge option greyed out or absent in Android settings after fitting a new cell. The charge protocol negotiation between the USB-PD controller and the battery management system requires at least one accepted standard charge cycle to re-establish the handshake. Plug in using the original charger and let the tablet complete one full charge at standard rate without unplugging early. Once that cycle completes, fast charge negotiation resumes normally on subsequent connections.

Compatible Models

AC101OX4G OXYGEN 4G

Replaces Part Numbers

3097138 29100145

Technical Specifications

Voltage3.7V
Amp Hours4400mAh
Capacity4400mAh
Rate16.28Wh
Net Weight75g /2.65 oz
Gross Weight125g /4.41 oz
Approximate Weight125g /4.41 oz
Dimension 132.20 x 93.50 x 2.80mm

Product Highlights

  • Brand: Archos
  • Manufacturer: CS
  • Color: Black
  • Product Type: Li-Polymer
  • Battery Type: Li-Polymer
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Archos AC101OX4G is showing 80% battery but just switched off — why?

The fuel gauge IC inside the tablet calibrated its shutdown voltage against the old, worn cell. A fresh 4400mAh cell has a different discharge curve, so the IC hits its low-voltage trip point before the displayed percentage catches up. Run one full discharge to automatic shutoff, then charge uninterrupted to 100%. After that single cycle, the IC recalibrates and the early shutdowns stop.

The battery percentage on my OXYGEN 4G jumps around after the swap — it went from 60% to 40% in minutes without heavy use.

That jump is fuel gauge drift — the IC is still reading voltage against the old cell's profile, so small voltage changes look like large capacity drops. The new 3.7V Li-Polymer cell needs one full reference cycle before the gauge tracks accurately. Discharge the tablet completely to automatic shutoff and charge straight to 100% without interruption. Percentage reporting stabilises after that first full cycle.

The tablet feels warm near the charging port while the new battery charges — is that a fault?

Mild warmth during the first few charge cycles on a new cell is normal. The charge IC on the AC101OX4G runs a conditioning pass on a new Li-Polymer cell, which generates slightly more heat than a settled cell absorbs. If the tablet becomes hot to the touch or the charge IC cuts off repeatedly, check that you are using a charger within the rated input spec for the tablet. Gentle warmth that fades after the first two or three charges is not a fault.