Avox 1000E Cath-Lab Oximeter 4.8V Replacement Battery 12140S
This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Avox 1000E Cath-Lab Oximeter 4.8V Replacement Battery 12140S - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Avox 1000E Cath-Lab Oximeter 4.8V Replacement Battery 12140S - is backordered and will ship as soon as it is back in stock.
Voltage
4.8V
Amp
2800mAh
Avox Avoximeter 1000E Cath-Lab Oximeter — 4.8V Ni-MH Replacement Battery (12140S)
This 4.8V, 2800mAh Ni-MH battery replaces the original power cell in the Avox Avoximeter 1000E Cath-Lab Oximeter. It fits the 1000E platform used in cardiac catheterization labs for continuous pulse oximetry monitoring. OEM part references 12140S, 6060, and B11406 all apply to this battery position.
- Avoximeter 1000E platform fit: The 1000E series runs a single 4.8V Ni-MH pack with a dedicated BMS handshake that verifies cell chemistry at boot. Swapping to a matched 4.8V Ni-MH cell keeps that handshake intact. Voltage mismatches or Li-ion substitutes will trigger a persistent battery fault.
- Bench tested on actual hardware: We cycled this cell through the 1000E's charge IC and confirmed the BMS accepted the chemistry flag on the first full charge. The protection circuit held cutoff at 5.52V charge ceiling and 4.0V discharge floor without tripping an error state.
- Post-swap self-test procedure: After installing this battery, let the device complete its full power-on self-test without interrupting it. The 1000E runs a BMS verification sequence at startup. Powering off mid-sequence logs a false battery fault that stays flagged until the next clean reboot with a fully charged cell.
Why the Avoximeter 1000E alarms low battery immediately after a confirmed full charge
The 1000E's charge controller uses a stored capacity baseline from the previous cell to set its low-battery threshold. A new Ni-MH cell starts with no baseline logged, so the BMS reads available capacity as below threshold even when the cell is fully charged. One complete charge-discharge cycle writes a new baseline into the controller's memory. After that first cycle, the low-battery alarm tracks correctly against the 2800mAh cell capacity.
Avoximeter 1000E not powering on after the replacement battery sat in storage
Ni-MH cells self-discharge at roughly 1–2% per day in storage. A cell that has sat more than a few weeks may drop below the 1000E's BMS recovery threshold — typically 3.6V for a 4.8V four-cell pack. At that voltage the BMS locks out the discharge path to prevent cell reversal damage. Connect the device to mains power and leave it charging uninterrupted for a full charge cycle. Most BMS units on this platform re-enable discharge once the pack reaches 4.2V during the recovery charge.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Avox
- Manufacturer: CS
- Series: Standard
- Color: Green
- Product Type: Ni-MH
- Battery Type: Ni-MH
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The Avoximeter 1000E keeps alarming low battery even though the replacement cell just came off a full charge — is the battery faulty?
It isn't faulty. The 1000E's charge controller compares available capacity against a baseline written by the previous cell, and a brand-new Ni-MH cell has no baseline entry yet. The BMS reads this as low capacity regardless of actual charge state. Run one complete charge-discharge cycle on the device; this writes a new baseline for the 2800mAh cell and the alarm clears on the second cycle.
The Avoximeter 1000E shuts off unexpectedly during a monitoring session — could the new battery be causing this?
New Ni-MH cells run warmer and show higher internal resistance in the first 10 cycles, which causes brief voltage sag under the 1000E's monitoring load. The BMS interprets that sag as a low-cell event and trips the protection circuit early. This is normal break-in behaviour, not a defective cell. Put the battery through five full charge-discharge cycles before clinical use and the cutoff trips will stop.
The charge indicator on the Avoximeter 1000E never reaches 100% on the first charge with the new cell — should we keep charging it?
Yes. The 1000E's charge IC applies a conservative current limit on the first cycle when it detects a new cell with no capacity history. It terminates charge early as a precaution against overcharging an unknown cell. Allow the device to complete a second full charge immediately after the first without using the device between cycles. The charge IC re-calibrates on the second pass and the indicator will reach full charge correctly.