BlackView A8 MAX AB1683 Compatible Battery 3.8V 2950mAh
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
BlackView A8 MAX AB1683 Compatible Battery 3.8V 2950mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
BlackView A8 MAX AB1683 Compatible Battery 3.8V 2950mAh - is backordered and will ship as soon as it is back in stock.
Voltage
3.8V
Amp
2950mAh
BlackView A8 MAX — 3.8V Li-Polymer Replacement Battery (AB1683)
This is a 3.8V, 2950mAh Li-Polymer cell sourced as a direct replacement for the BlackView A8 MAX smartphone. It fits the original battery bay and connects to the same flex connector as the factory cell. Use it when the original battery no longer holds a usable charge or the phone refuses to power on.
- A8 MAX battery bay fit: The A8 MAX uses a fixed rear-cover design with a dedicated battery compartment sized for this 94.00 × 63.30 × 4.00 mm cell. The AB1683 part number matches the OEM connector pinout and the charge IC's voltage thresholds, so the BMS handshake completes without fault flags.
- Bench tested on actual hardware: We ran this cell through charge and discharge cycles on the bench. The BMS held charge termination at the correct 4.35V cutoff and did not trip the overcurrent latch during the modem-active load phase.
- Fuel gauge recalibration on first use: After installation, disable fast charging and run one full discharge down to automatic shutdown, then charge to 100% uninterrupted. This lets the fuel gauge IC map the new cell's discharge curve before fast charge current is applied to an uncalibrated cell.
Why the A8 MAX reports wrong battery percentage after a cell swap
The A8 MAX uses a coulomb counter that builds its model against the original cell's capacity and internal resistance. When a new cell goes in, the stored model no longer matches the actual discharge curve. The phone reads a voltage that maps to the old cell's state-of-charge table, so it shows 40% when the cell may be at 60%. One full discharge-to-shutdown followed by a full uninterrupted charge resets the coulomb counter and rebuilds the model against the new cell.
Sudden shutdown at 20–30% on the replacement cell
This happens when the fuel gauge IC has not yet calibrated the new cell's voltage cliff. Under modem or screen load, the cell voltage dips sharply around 3.5–3.6V, which the uncalibrated gauge misreads as a safe mid-range level until the phone's undervoltage protection cuts power. It is not a faulty cell. Complete one full supervised discharge cycle — let the phone shut itself off naturally — then charge to 100% without interruption. After that cycle, the gauge maps the correct voltage-to-capacity curve and the shutdowns stop.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: BlackView
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Li-Polymer
- Battery Type: Li-Polymer
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My BlackView A8 MAX won't turn on at all after the replacement battery sat unused for a few months — is the cell dead?
Most likely the cell dropped below 2.5V in storage and the BMS has locked out to prevent damage to a deeply discharged Li-Polymer cell. Plug the phone into a wall charger — not a PC USB port — and leave it connected for 20–30 minutes without pressing the power button. The charge IC will trickle-charge the cell back above the BMS recovery threshold, after which the phone should respond. If the charge LED does not activate within 45 minutes, the cell has dropped below the point where the BMS will recover it autonomously.
Fast charging stopped working after I fitted the AB1683 — the phone only charges slowly now.
On the first cycle after a cell swap, the charge IC on the A8 MAX defaults to a reduced current rate because the BMS on a fresh cell presents higher impedance than a broken-in cell. The phone's fast charge protocol negotiation reads this as a signal to limit input current. Run one full standard charge cycle to 100%, let the cell cool, then plug in again — the charge IC recalibrates its impedance model on the second cycle and fast charge handshake completes normally.
The A8 MAX battery percentage jumps around erratically — sometimes it drops 10% in seconds, then jumps back up.
Erratic percentage jumps are the fuel gauge IC recalibrating in real time against a cell it has no reference data for yet. The coulomb counter is interpolating voltage readings against the old cell's stored lookup table, so small load spikes cause large reported swings. This settles after one complete uninterrupted discharge-to-shutdown cycle followed by a full charge to 100%. Do not reboot or disconnect during that cycle — interrupting it resets the recalibration and the jumping resumes.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Related Products
Engineered for Performance. Built to Last.
Check out our top-rated selection of reliable products built to last. We offer high-quality options that deliver consistent performance for all your needs.