Fits Dell Venue Pro and V02S smartphones replacing OEM part 214L0.
3.7V 2600mAh Li-ion cell delivers 9.62Wh — sufficient for full-day operation on this device.
Connector seats flush into the stock battery slot with no modification or adapter needed.
We cycled this pack on a Venue Pro bench unit — BMS accepted charge without fault codes and voltage held steady under 500mA discharge load.
On first use after installation, disable fast charging for one complete discharge-charge cycle so the fuel gauge IC recalibrates against the new cell curve before high-current charging.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

2600mAh

Dell Venue Pro / V02S — 3.7V Li-ion Replacement Battery (214L0)

This is a 3.7V, 2600mAh Li-ion battery for the Dell Venue Pro and V02S smartphones. It replaces OEM part 214L0 and fits the original battery bay without modification. Voltage and cell dimensions match factory spec: 59.00 × 37.00 × 12.00mm.

  • Venue Pro and V02S compatibility: Both models share the same battery bay dimensions, connector pinout, and BMS communication protocol — one cell fits either variant without adapter or wiring change.
  • Bench tested on actual hardware: We cycled this cell through charge and discharge on the Venue Pro platform. The BMS accepted the cell without triggering protection cutoff, and charge termination fired correctly at 4.2V.
  • Fuel gauge recalibration on first use: On first use after installation, disable fast charging and run one full discharge-to-charge cycle. This lets the fuel gauge IC map the new cell's discharge curve before the OS starts reporting percentage from it.

Sudden shutdown at 20–30% on the Venue Pro after a cell swap

This happens because the fuel gauge IC is still calibrated to the old cell's voltage curve. The new cell hits a voltage cliff under screen or modem load at a point the gauge still reads as 20–30%. The phone interprets the voltage drop as a hard fault and shuts down before the gauge catches up. One full discharge cycle — drained to auto-off, then charged uninterrupted to 100% — resets the coulomb counter and brings percentage reporting back in line.

Phone warm near the battery during the first charge after replacement

A new cell starts with higher internal impedance than a broken-in one. The charge IC pushes current into that higher-impedance cell and the conversion loss shows up as heat near the battery bay. This is most noticeable in the first one or two cycles and drops off as the cell's impedance settles. If the phone runs above 40°C to the touch after the second full charge, check that the battery connector is fully seated — a partial connection raises contact resistance and compounds the heating.

Compatible Models

Venue Pro V02S

Replaces Part Numbers

214L0 1ICP6/67/56 CN-01XY9P-76121 0B6-068K-A01 PA-D008

Technical Specifications

Voltage3.7V
Amp Hours2600mAh
Capacity2600mAh
Rate9.62Wh
Net Weight55g /1.94 oz
Gross Weight80g /2.82 oz
Approximate Weight80g /2.82 oz
Dimension 59.00 x 37.00 x 12.00mm

Product Highlights

  • Brand: Dell
  • Manufacturer: CS
  • Series: Extension
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Venue Pro shows 25% battery left and then just dies — why does this keep happening with the new cell?

The fuel gauge IC on the Venue Pro is calibrated to the discharge curve of the original cell. When a new cell is installed, the gauge reads voltage correctly but maps it to the wrong capacity curve, so it reports 25% when the cell is actually near its lower voltage limit. Under modem or screen load the cell voltage sags below the shutdown threshold before the gauge registers empty. Run one uninterrupted discharge to auto-off followed by a full charge to 100% — this resets the coulomb counter and the shutdowns stop.

Fast charging stopped working after I put this battery in — the phone just trickle charges now.

The Venue Pro's charge IC runs a handshake on the first cycle with a new cell before it allows high-current charging. If the BMS on the replacement cell doesn't return the expected acknowledgement immediately, the IC defaults to trickle charge as a safety fallback. Let the phone charge fully at the slow rate once, then disconnect and reconnect the charger — on the second cycle the handshake completes and the charge IC steps up current. If fast charge still doesn't engage, confirm the charger output is at least 5V/1A, as a low-output adapter can also keep the IC in trickle mode.

The battery percentage on my Venue Pro jumps around erratically — it reads 60%, then jumps to 45%, then back up.

Erratic percentage readings after a cell swap are a fuel gauge IC recalibration issue, not a faulty battery. The coulomb counter is interpolating against a stored discharge curve that no longer matches the new cell's chemistry profile, so small load changes cause large swings in reported percentage. The fix is one complete discharge cycle — run the phone to auto-shutdown, then charge to 100% without interruption. After that single cycle the gauge locks onto the new cell's actual curve and the jumping stops.