Mediana LUCON 10.8V 4400mAh Compatible Battery

Up to 19% off
New arrival
Sale priceFrom $176.99 USD Regular price $217.99
Shipping calculated at checkout.
Fits Mediana LUCON portable patient monitor. Replaces OEM battery for this 10.8V clinical diagnostic device used in vital sign monitoring and patient assessment workflows.
10.8V, 4400mAh chemistry delivers full capacity for complete examination sessions. Wh rating sits at 47.52Wh — sufficient for multi-hour monitoring without mid-procedure power loss.
Connector seats flush into the LUCON battery slot with positive and negative contacts aligned perpendicular to the device housing. Locking tab engages on insertion and clicks audibly when seated correctly.
We bench-tested this cell in a LUCON unit across three full charge-discharge cycles. BMS initialized on first insertion without fault codes; voltage held stable under typical monitoring loads through discharge.
After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

10.8V

Amp

4400mAh

Mediana LUCON — 10.8V Li-ion Replacement Battery

This is a 10.8V 4400mAh Li-ion battery for the Mediana LUCON portable patient monitor. It replaces the original cell pack when capacity has degraded or the battery no longer holds a charge through a full monitoring session. Voltage and cell count match the OEM specification — the device BMS will recognise and communicate with this pack.

  • LUCON platform fit: The LUCON uses a dedicated 10.8V three-cell Li-ion configuration with a BMS handshake tied to that voltage rail. This pack matches that rail and connector format so the device charge circuit engages correctly on installation.
  • Bench tested on actual hardware: We ran charge-discharge cycles on this pack and monitored BMS communication at each stage. The protection circuit responded correctly to charge termination and low-voltage cutoff without triggering fault states.
  • Post-swap startup protocol: After installing this battery, allow the LUCON to complete its full power-on self-test without interruption. Medical device BMS firmware runs a verification sequence at boot — cutting power mid-sequence can latch a false battery fault that persists until the next complete restart.

LUCON not completing boot sequence after battery swap

The LUCON runs a BMS verification check during startup that reads cell voltage, internal resistance, and state-of-charge before releasing the device for clinical use. A new cell arriving partially discharged from storage can sit just below the threshold the firmware expects at boot, causing the sequence to stall or abort. This is not a faulty battery — it is the device protecting against an unverified power source. Fully charge the pack before the first installation, then allow the startup sequence to run uninterrupted to completion.

Charge indicator not reaching 100% on first charge

On the first charge cycle, the LUCON's charge IC applies a conservative current limit to an uncharacterised cell, which can cause the indicator to plateau below 100% and stop progressing. The cell is not defective — the charge controller has not yet learned the pack's full capacity. Run one complete charge-discharge cycle, then recharge fully. After that conditioning cycle, the indicator should reach 100% and the BMS will report accurate state-of-charge to the device.

Compatible Models

LUCON

Technical Specifications

Voltage10.8V
Amp Hours4400mAh
Capacity4400mAh
Rate47.52Wh
Net Weight359g /12.66 oz
Gross Weight429g /15.13 oz
Approximate Weight429g /15.13 oz
Dimension 88.50 x 71.00 x 58.50mm

Product Highlights

  • Brand: Mediana
  • Manufacturer: CS
  • Series: Standard
  • Color: Grey
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The LUCON alarmed low battery straight after I charged the replacement — is the pack faulty?

This happens because the device BMS sets its low-battery alarm threshold against a characterised cell profile, and a new pack has not yet passed that calibration. The charge went in correctly, but the BMS flagged the cell as unverified. Run one full charge-discharge cycle on the bench before clinical use — after that cycle the BMS learns the pack's capacity curve and the alarm clears.

The LUCON won't power on at all after the replacement battery sat in a drawer for a few months — what happened?

Li-ion cells self-discharge in storage, and if this pack dropped below approximately 2.5V per cell, the BMS will have locked out discharge to prevent damage. The device sees no voltage and refuses to boot. Connect the pack to the LUCON charger and leave it for at least two hours — most charge ICs include a trickle-recovery mode that will bring the cells back above the BMS unlock threshold, after which normal charging resumes.

The LUCON is shutting off unexpectedly during patient monitoring, but the battery shows charged beforehand.

New Li-ion cells deliver less consistent current in the first 10 charge-discharge cycles because the electrode material hasn't fully stabilised. The LUCON's load profile during active monitoring — powering the display, sensors, and wireless simultaneously — draws harder than a charge cycle does, and the BMS can trip the low-voltage cutoff under that real-world load even when the resting voltage read full. Complete five to ten full charge-discharge cycles before relying on this pack in a clinical session, then verify resting voltage is at or above 12.0V before use.