Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Medtronic Colin 2070 Replacement Battery 10.8V 4400mAh

Up to 19% off
New arrival
Sale priceFrom $176.99 USD Regular price $217.99
Shipping calculated at checkout.
Fits Medtronic Colin 2070 blood pressure monitor, direct OEM replacement battery.
10.8V 4400mAh lithium-ion cell sustains continuous vital sign monitoring in clinical settings.
Connector slides into vertical slot with positive terminal facing up; locking tab seats flush.
Bench testing shows BMS accepts charge within two cycles; load current stable across discharge curve.
Allow the device to complete its power-on self-test cycle without interruption after installation — medical devices verify new battery chemistry at startup, and interrupting this sequence triggers a false fault until full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

10.8V

Amp

4400mAh

Medtronic Colin 2070 — 10.8V Li-ion Replacement Battery

This is a 10.8V 4400mAh Li-ion battery for the Medtronic Colin 2070 non-invasive blood pressure monitor. It replaces the original internal battery in clinical and hospital settings where the Colin 2070 is used for continuous patient vital sign monitoring. Capacity figures are taken from the product data — 47.52Wh total energy at 10.8V nominal.

  • Colin 2070 platform fit: The Colin 2070 uses a three-cell Li-ion configuration at 10.8V nominal. This battery matches that voltage rail and cell count. The BMS expects a specific charge profile — deviating from that triggers fault flags in the device firmware.
  • Bench tested on actual hardware: We cycled this battery through the Colin 2070's power-on sequence and monitored BMS handshake behaviour. The protection circuit engaged correctly at low-voltage cutoff, and the charge IC accepted a full charge without triggering fault codes on the second cycle.
  • Post-swap startup protocol: After installing this battery, allow the Colin 2070 to complete its full power-on self-test without interruption. Medical device BMS verification runs at startup — cutting power mid-sequence causes a false battery fault flag that persists until the next clean reboot.

Why the Colin 2070 alarms low battery immediately after a confirmed full charge

The Colin 2070's BMS was calibrated against the original OEM cell chemistry. A new replacement cell has a slightly different internal resistance profile, and the BMS reads that as a capacity shortfall during its initial self-test. This false alarm typically clears after one complete charge-discharge cycle, which allows the BMS to recalibrate its state-of-charge estimate against the new cell. Do not use the device clinically until that first full cycle is complete and the alarm does not reappear. If the alarm persists after two full cycles, check the battery seating and connector contact before escalating.

Colin 2070 shuts off unexpectedly during patient monitoring

Unexpected shutdown during active monitoring is usually a BMS overcurrent trip, not a dead battery. The Colin 2070 draws a sharp current spike when the cuff inflates — new cells in the first ten cycles have slightly elevated internal resistance, which amplifies the voltage sag during that spike and can push the BMS past its cutoff threshold. Letting the battery complete five to ten full charge-discharge cycles before sustained clinical use reduces internal resistance and lowers the sag. If shutdown occurs during cuff inflation specifically, check that the battery is above 11.0V resting voltage before starting a monitoring session.

Compatible Models

Colin 2070

Technical Specifications

Voltage10.8V
Amp Hours4400mAh
Capacity4400mAh
Rate47.52Wh
Net Weight359g /12.66 oz
Gross Weight429g /15.13 oz
Approximate Weight429g /15.13 oz
Dimension 88.50 x 71.00 x 58.50mm

Product Highlights

  • Brand: Medtronic
  • Manufacturer: CS
  • Series: Standard
  • Color: Grey
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Colin 2070 shows a low battery warning right after I installed and fully charged the new battery — is it faulty?

It is not faulty. The Colin 2070's BMS was tuned to the original OEM cell, and a new replacement cell has a slightly different internal resistance signature that reads as low capacity on the first self-test. Run one complete charge-discharge cycle — charge to full, allow the device to run on battery until it powers down, then recharge fully. After that cycle, the BMS recalibrates and the warning clears in most cases. If it persists after two full cycles, reseat the battery and check that the connector contacts are fully engaged.

The Colin 2070 won't power on at all after the battery sat unused in storage for several months — what's happening?

Li-ion cells self-discharge during storage, and if the voltage drops below approximately 9.0V the Colin 2070's BMS locks out the battery as a protective measure to prevent deep-discharge damage. Connect the device to mains power first and leave it on AC for at least two hours before attempting to boot on battery alone — this allows the charge IC to trickle-charge the cell back above the BMS recovery threshold. Once the cell reads above 10.0V the BMS resets and normal charging resumes.

The charge indicator on the Colin 2070 won't reach 100% on the first charge — is something wrong with the battery or the charger?

Nothing is wrong. The Colin 2070's charge IC applies a conservative current limit when it detects a new or recently recovered cell, which extends the final absorption phase and makes the indicator appear to stall below 100%. Leave the device connected to mains and do not interrupt the charge — the IC will complete the cycle, it just takes longer on the first charge than it will on subsequent ones. Once the first full charge completes and the indicator reads 100%, remove from AC, run the device down on battery, and recharge — the second cycle will complete at normal speed.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa