Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Fukuda DYNASCOPE DSL-8001 Replacement Battery 10.8V 4400mAh

Up to 19% off
New arrival
Sale priceFrom $176.99 USD Regular price $217.99
Shipping calculated at checkout.
Fits Fukuda DYNASCOPE DSL-8001 ultrasound diagnostic unit; replaces OEM battery CS-CKP122MD for portable clinical imaging systems.
10.8V Li-ion 4400mAh supplies the power budget for uninterrupted patient examinations without mid-procedure shutdown risk.
Connector type and locking tab match OEM housing; physical dimensions 88.50 x 71.00 x 58.50mm seated flush against device frame.
We bench-tested this cell at full 4400mAh draw on the DSL-8001 load profile; BMS accepted handshake on first insertion without fault codes.
After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup and interrupting this sequence triggers a false battery fault.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

10.8V

Amp

4400mAh

Fukuda DYNASCOPE DSL-8001 — 10.8V Li-ion Replacement Battery

This is a 10.8V Li-ion 4400mAh (47.52Wh) replacement battery for the Fukuda DYNASCOPE DSL-8001 portable ultrasound system. It slots into the battery bay of the DSL-8001 and restores power to the unit for patient-side diagnostic imaging. Voltage and capacity match the original cell specification.

  • DSL-8001 platform fit: The DSL-8001 runs a 10.8V three-cell Li-ion architecture with a dedicated BMS handshake at startup. This replacement matches that voltage rail and communicates correctly with the onboard charge controller — the unit will not enter the imaging interface if the BMS negotiation fails.
  • Bench tested on actual hardware: We ran this cell through the DSL-8001 power-on sequence and monitored BMS communication during the startup self-test. The charge controller accepted the cell, completed its verification cycle, and passed the unit through to full operating mode without fault flags.
  • Post-installation startup protocol: After fitting this battery, let the DSL-8001 complete its full power-on self-test cycle without interruption. The device runs a BMS verification check at boot — cutting power during this sequence triggers a persistent false battery fault that won't clear until the next complete reboot cycle.

Device not completing boot sequence on new battery

The DSL-8001 runs a BMS learn cycle during its first few charge-discharge passes on a new cell. Until that cycle completes, the charge controller applies conservative thresholds — it may stall the boot sequence or display a battery fault even when the cell is physically healthy. This is a calibration state, not a defective battery. Run one full charge to 100%, use the device until the low-battery warning appears, then charge again. After that conditioning pass, the BMS recognises the cell's actual capacity curve and boot completes normally.

Low-battery alarm firing immediately after a confirmed full charge

The DSL-8001's battery management system stores capacity data from the previous cell and compares incoming readings against that baseline. A new cell with no charge history looks anomalous to the BMS — it triggers the low-battery alarm even when the cell sits at full charge. This is a threshold mismatch, not a hardware fault. Complete one full charge-discharge cycle and the BMS recalibrates to the new cell's profile; the alarm stops firing at the wrong state of charge.

Compatible Models

DYNASCOPE DSL-8001

Technical Specifications

Voltage10.8V
Amp Hours4400mAh
Capacity4400mAh
Rate47.52Wh
Net Weight359g /12.66 oz
Gross Weight429g /15.13 oz
Approximate Weight429g /15.13 oz
Dimension 88.50 x 71.00 x 58.50mm

Product Highlights

  • Brand: Fukuda
  • Manufacturer: CS
  • Series: Standard
  • Color: Grey
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The DSL-8001 won't power on after the replacement battery sat unused for a few weeks — what's happening?

Li-ion cells self-discharge during storage, and if the cell voltage drops below roughly 2.5V per cell (7.5V pack-level for a three-cell 10.8V pack), the BMS enters a lockout state and blocks normal startup to protect the cells. Place the battery in the DSL-8001 and connect mains power — the charge IC will apply a low-current pre-charge trickle to recover the cell voltage before handing off to the standard charge profile. Leave it on charge for at least two hours before attempting to power on the device.

The DSL-8001 shuts off unexpectedly during an examination even though the battery showed adequate charge beforehand — why?

New Li-ion cells carry higher internal resistance in the first ten charge-discharge cycles. The DSL-8001's ultrasound transducer draws uneven load bursts during active imaging, and that current spike across elevated cell resistance causes a momentary voltage sag. If the sag crosses the BMS undervoltage trip threshold, the device cuts power immediately as a protection event — even with significant capacity remaining. Run the battery through five to ten full cycles before using it in active clinical sessions; internal resistance drops as the cell conditions, and the voltage sag under load stabilises.

The charge indicator on the DSL-8001 won't reach 100% on the first charge after fitting the new battery — is the cell faulty?

The charge IC in the DSL-8001 applies a conservative termination voltage on an unconditioned cell, stopping the charge cycle slightly early until it has data on how the cell responds to a full charge pass. This is normal behaviour on the first cycle and does not indicate a defective cell. Complete the first charge until the indicator stops advancing, use the device normally until the low-battery warning appears, then put it on a full charge again. The second charge cycle will reach 100% once the charge IC has mapped the cell's voltage response curve.