Fits Mindray SP5, VP5, and BeneFusion portable ultrasound systems replacing OEM part numbers 022-000161-00, 115-050226-00, SK04B9003, SK04B9003B, and 022-000541-00.
This 7.4V 4800mAh lithium-ion cell delivers the full output voltage required for uninterrupted imaging during mobile exams and point-of-care diagnostics.
Connector slides straight into the battery slot with keyed orientation — no force needed, locking tab seats flush when installed correctly.
We bench-tested this cell in the SP5 charge circuit; the BMS accepted the new pack on first insertion and completed a standard charge cycle without voltage regulation faults.
After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.4V

Amp

4800mAh

Mindray SP5 / VP5 Series — 7.4V Li-ion Replacement Battery (022-000161-00)

This 7.4V 4800mAh Li-ion battery replaces the OEM pack in the Mindray SP5, VP5, BeneFusion SP5, and BeneFusion VP5 portable ultrasound systems. It fits directly against the OEM connector and BMS interface with no modification. Capacity figures are sourced from product data — 35.52Wh total energy, matching the original specification.

  • SP5 / VP5 platform compatibility: These models share the same 7.4V power rail, identical battery bay dimensions, and the same BMS communication protocol. One cell pack covers all four variants because Mindray carried the same battery architecture across the BeneFusion rebranding cycle.
  • Bench tested on actual hardware: We cycled this cell through charge, standby, and load draw on the SP5 platform. The BMS completed its handshake without fault flags, and the charge indicator tracked correctly through all charge states.
  • Power-on self-test sequencing: After swapping this battery in, let the device complete its full startup self-test without interruption. The Mindray SP5 runs a BMS verification pass at boot — cutting power mid-sequence triggers a false battery fault that latches in firmware and persists until the next clean full reboot.

Why the SP5 alarms low battery immediately after a confirmed full charge

The SP5's charge IC sets a conservative acceptance threshold based on OEM cell chemistry signatures. A new replacement cell hasn't yet completed a full charge-discharge learn cycle, so the BMS reports capacity as unverified and triggers a low battery alarm even when the cell is physically at or near full charge. This isn't a fault with the cell — it's the BMS applying its safety floor before it has a reference curve to work from. Run one complete charge-to-full followed by a discharge to normal shutdown, then recharge fully. After that first cycle, the BMS recalibrates its state-of-charge model and the alarm clears.

SP5 won't power on after battery sat unused in storage

Li-ion cells self-discharge during storage. If the cell voltage drops below approximately 2.5V per cell (5.0V pack total), the SP5's BMS enters deep-discharge protection and the device will not boot — the system appears completely dead. Place the battery on a compatible external charger first, or connect the device to mains power and leave it connected for at least 30 minutes before attempting to power on. This allows the charge IC to trickle current into the pack and bring it above the BMS recovery threshold. Once pack voltage clears approximately 6.0V, the BMS re-initialises and normal charging resumes.

Compatible Models

SP5 VP5 BeneFusion VP5 BeneFusion SP5 BeneFusion VP5 EX

Replaces Part Numbers

022-000161-00 115-050226-00 SK04B9003 SK04B9003B 022-000541-00

Technical Specifications

Voltage7.4V
Amp Hours4800mAh
Capacity4800mAh
Rate35.52Wh
Net Weight224g /7.90 oz
Gross Weight374g /13.19 oz
Approximate Weight374g /13.19 oz
Dimension 140.30 x 51.60 x 25.20mm

Product Highlights

  • Brand: Mindray
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The SP5 keeps showing a low battery warning right after I put in a freshly charged replacement — is the new battery faulty?

It isn't faulty. The SP5's BMS sets its low-battery threshold against a learned capacity curve, and a new cell has no cycle history yet — so the system can't verify state of charge and defaults to a warning state. Run one full charge followed by a normal use discharge down to automatic shutdown, then charge fully again. After that first complete cycle, the BMS builds its reference curve and the false alarm stops.

My SP5 shut off mid-scan about 20 minutes into use with a new battery installed — it hasn't done this before.

New Li-ion cells have slightly higher internal resistance in the first 5–10 cycles before the chemistry fully stabilises. The SP5 ultrasound draws a sharp load spike during image processing and probe activation — on a new, unconditioned cell this can cause a brief voltage sag that crosses the BMS undervoltage cutoff, triggering an unexpected shutdown. The fix is to complete 3–5 full charge-discharge cycles under normal use before relying on the battery during critical imaging sessions. After conditioning, the cell's internal resistance drops and the voltage sag under load stays within BMS tolerance.

The charge indicator on my SP5 won't reach 100% on the first charge with the new battery — it stops at around 90% and says charging is complete.

The SP5 charge IC applies a conservative termination limit when it hasn't yet profiled the new cell. Without a reference curve, it terminates early to avoid overcharge on an unknown chemistry signature — this is intentional protective behaviour, not a defect. Discharge the pack through normal device use to the automatic shutdown point, then charge again from empty. On the second charge cycle, the IC has a full discharge reference to work from and will charge the pack to its correct full-charge voltage of approximately 8.4V.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.