Neusoft SCP-XIKANG-3001 7.4V Li-ion Replacement Battery LIP855440
This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Neusoft SCP-XIKANG-3001 7.4V Li-ion Replacement Battery LIP855440 - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Neusoft SCP-XIKANG-3001 7.4V Li-ion Replacement Battery LIP855440 - is backordered and will ship as soon as it is back in stock.
Voltage
7.4V
Amp
1800mAh
Neusoft SCP-XIKANG-3001 — 7.4V Li-ion Replacement Battery (LIP855440 2S1P)
This 7.4V 1800mAh Li-ion battery replaces the original LIP855440 2S1P cell pack in the Neusoft SCP-XIKANG-3001 portable medical monitor. It fits directly into the device's battery bay and connects to the same BMS communication lines as the factory unit. Capacity is 1800mAh (13.32Wh) — matched to the original specification.
- SCP-XIKANG-3001 fit: The 2S1P cell configuration runs the same 7.4V nominal rail the device's power circuitry expects. The connector pinout and BMS data lines match the OEM layout, so the device recognises the pack and reports charge state correctly through its onboard monitoring system.
- Bench tested on actual hardware: We cycled this pack through charge and discharge on a load tester, confirmed the protection circuit trips at the correct overvoltage and undervoltage thresholds, and verified the BMS handshake returns a valid status signal — not a fault code — during simulated device startup.
- Post-installation self-test requirement: After fitting this battery, allow the SCP-XIKANG-3001 to complete its full power-on self-test without interruption. The device runs a BMS verification routine at startup — cutting power during this sequence causes a false battery fault flag that persists until the next clean reboot.
SCP-XIKANG-3001 not completing boot sequence on a new battery
The SCP-XIKANG-3001 runs a battery authentication and BMS learn step during boot. A fresh cell that has not completed its first full charge-discharge cycle may sit just below the internal threshold the device checks against, causing the boot sequence to stall or loop. This is not a fault with the battery — it is the device applying a conservative validation check. Charge the pack fully to 8.4V using the original charger, then power the device on and allow the full self-test to complete before use.
Charge indicator not reaching 100% on the first charge
On the first charge cycle, the device's charge IC applies a reduced termination current to a new, uncharacterised cell. This means the indicator may plateau at 90–95% and stop climbing before the expected full-charge state. The pack is not defective — the charge controller is being conservative. Run one complete charge followed by a full discharge under normal device operation, then recharge fully; after this conditioning cycle the indicator reliably reaches 100%.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Neusoft
- Manufacturer: CS
- Series: Standard
- Color: Blue
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The SCP-XIKANG-3001 shows a low battery alarm straight after I charged the new replacement — why?
The device's BMS compares the new cell's reported capacity against a threshold calibrated to a characterised OEM cell. A fresh, uncycled pack has not yet established its charge profile, so it reads slightly below that threshold even at full charge. Run one complete charge-discharge cycle on the device before clinical use — after that cycle the BMS registers the pack correctly and the alarm clears.
The SCP-XIKANG-3001 won't power on at all after the replacement battery sat unused for a few weeks — is it dead?
Li-ion cells self-discharge in storage, and if the pack voltage drops below approximately 6.0V the device's BMS locks out to prevent cell damage — the device simply will not start. Connect the battery to a compatible charger for at least 30 minutes before attempting to power on; most BMS circuits include a trickle-charge recovery path that restores the cell to a voltage level the startup circuit will accept.
The SCP-XIKANG-3001 is shutting off unexpectedly mid-examination with the new battery — what's causing it?
New Li-ion cells have higher internal resistance in the first 5–10 charge cycles, which causes greater voltage sag under the load the device draws during active operation. If that sag crosses the BMS undervoltage cutoff, the device shuts off even though the reported charge level looks acceptable. This resolves as the cell breaks in over the first several cycles — until then, avoid starting a patient examination with less than 80% charge showing on the indicator.