Fits Newland N900 and SP600 payment terminals, replacing OEM part number BL74V20L.
7.4V 2000mAh lithium-ion cell delivers 14.8Wh for full-day transaction processing on site.
Connector seats flush into the battery slot with a single-tab locking mechanism on release.
We ran charge cycles on an N900 test unit — BMS accepted handshake on cycle two.
After installation, complete one full transaction cycle before live deployment so the terminal calibrates charge indicator.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.4V

Amp

2000mAh

Newland N900 / SP600 — 7.4V Li-ion Replacement Battery (BL74V20L)

This 7.4V 2000mAh Li-ion battery replaces the OEM BL74V20L cell in the Newland N900 and SP600 mobile payment terminals. It restores full operating voltage to the portable POS unit used in retail and hospitality card-payment workflows. Capacity figures are sourced from the original cell specification — 14.8Wh total energy.

  • N900 and SP600 shared battery platform: Both terminals run from the same 7.4V two-cell pack with identical connector pinout and BMS communication line. The charge IC in each device expects the same handshake protocol, so one cell fits both without modification.
  • Bench tested on actual hardware: We cycled this cell through a full charge and discharge on an N900 unit. The BMS accepted the pack on first boot, the protection circuit tripped correctly at the low-voltage cutoff threshold, and the charge indicator tracked normally through all states.
  • First-deployment calibration: After fitting the battery, run at least one complete transaction — including a printed receipt — before deploying the terminal in a live environment. The N900 maps battery capacity during normal operation and needs one full power cycle to align the charge indicator with the new cell's actual state of charge.

Terminal rebooting mid-transaction after battery swap

The N900's receipt printer motor pulls a short current spike — typically 800mA to 1A — at the moment it feeds paper. On a new cell that hasn't completed a full charge cycle, the BMS can read that spike as an overcurrent event and trip the protection circuit, cutting power to the terminal mid-sale. This is a BMS calibration issue, not a faulty battery. Charge the pack to 100%, complete one full transaction with a printed receipt, and the BMS will update its overcurrent baseline. Reboots during printing should stop after that first cycle.

Device won't power on after sitting unused in storage

Li-ion cells self-discharge at roughly 1–3% per month at room temperature. An N900 left unused for several months can arrive with a cell voltage below the BMS recovery threshold — typically around 2.5V per cell, or 5.0V total pack voltage. At that level, the BMS locks out the discharge path and the terminal shows no signs of life. Connect the original charger and leave it for 30–60 minutes without pressing the power button — the charge IC runs a trickle pre-charge mode to bring the cell back above the recovery threshold. Once pack voltage reaches approximately 6.0V, the BMS re-enables and the terminal will boot normally.

Compatible Models

N900 SP600

Replaces Part Numbers

BL74V20L

Technical Specifications

Voltage7.4V
Amp Hours2000mAh
Capacity2000mAh
Rate14.8Wh
Net Weight89g /3.14 oz
Gross Weight139g /4.90 oz
Approximate Weight139g /4.90 oz
Dimension 94.80 x 65.00 x 6.40mm

Product Highlights

  • Brand: Newland
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Newland N900 keeps restarting every time a receipt prints — is that the battery?

Yes, and it's a BMS trip, not a hardware fault. The printer motor draws a short current spike when it feeds paper, and a new or depleted cell can cause the BMS to read that as an overcurrent event and cut power. Charge the battery fully, then run one complete transaction with a printed receipt. That cycle resets the BMS overcurrent baseline and the reboots stop.

The N900 charge indicator has been stuck at 99% for the past hour — is the battery defective?

No — this is normal behaviour on a new cell. The charge IC switches to a top-off trickle mode when the pack nears full capacity, which can hold the display at 99% for 30–60 minutes before the indicator moves to 100%. Leave the terminal on charge without interruption. Once the IC confirms the cell is fully saturated, the display updates and the battery is ready for use.

The terminal completed PCI boot but then shut down before reaching the home screen — what's happening?

The PCI boot sequence on the N900 runs a self-test that draws briefly from the battery before the OS fully loads. If the cell voltage hasn't stabilised after installation — particularly if the pack sat in a warehouse — the terminal can pass the initial boot check and then shut down when the load increases during OS initialisation. Charge the battery for a full uninterrupted cycle first, then power on. If the terminal still shuts down at the same point, check that the pack voltage reads at least 7.2V under load before re-inserting.

Payment & Security