PARA Orange Yumo G740 Replacement Battery 3.8V 2300mAh
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
PARA Orange Yumo G740 Replacement Battery 3.8V 2300mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
PARA Orange Yumo G740 Replacement Battery 3.8V 2300mAh - is backordered and will ship as soon as it is back in stock.
Voltage
3.8V
Amp
2300mAh
PARA Orange Yumo G740 — 3.8V Li-ion 2300mAh Replacement Battery
This is a 3.8V Li-ion cell rated at 2300mAh (8.74Wh), sized as a direct fit for the Orange Yumo G740 smartphone. It replaces a degraded original cell that can no longer hold charge under typical call, screen, and data load. Dimensions are 100.00 x 41.45 x 4.50mm — measure your original before fitting if you are unsure.
- Orange Yumo G740 fitment: The G740 uses a fixed connector and BMS handshake tied to the 3.8V nominal rail. Swapping a cell outside that voltage spec causes the charge IC to reject the battery or report incorrect state-of-charge from the first cycle.
- Bench tested on actual hardware: We ran this cell through charge and load cycles on the G740 platform. The BMS accepted the new cell without fault codes, and the charge IC progressed through CC and CV phases normally without cutoff errors.
- Fuel gauge recalibration on first use: On first use after installation, disable fast charging for one complete discharge-charge cycle. This lets the fuel gauge IC recalibrate against the new cell's discharge curve before high-current charging pushes current into an uncalibrated cell.
Sudden shutdown at 20–30% on the replacement cell
A fresh cell with a different internal resistance profile hits a voltage cliff earlier than the fuel gauge IC expects. Under modem transmission bursts or screen-at-full-brightness load, the cell voltage drops below the BMS cutoff threshold even when the OS shows 25% remaining. The fuel gauge IC is still calibrated to the old cell's discharge curve, so the percentage reading lags behind actual cell state. One full discharge to auto-shutdown followed by a complete charge cycle resets the coulomb counter and resolves premature cutoffs.
OS reporting wrong battery percentage after cell swap
The G740's fuel gauge IC uses a stored discharge curve to calculate remaining capacity. When the original cell is replaced, that stored curve no longer matches the new cell's behaviour. The result is percentage jumps — often skipping from 40% to 10% — or a reading that freezes and then drops suddenly. Fully discharge the phone until it shuts off automatically, then charge uninterrupted to 100% without fast charging enabled; the coulomb counter resets to the new cell's actual curve at that point.
Compatible Models
Technical Specifications
Product Highlights
- Brand: PARA
- Manufacturer: CS
- Series: X-Longer
- Color: Black
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My Orange Yumo G740 keeps shutting off at around 25% after fitting the new battery — what's causing it?
The fuel gauge IC on the G740 is still reading off the old cell's discharge curve, so it doesn't see the voltage drop coming under load. When the modem or screen pulls a current spike, the new cell's voltage drops below the BMS cutoff before the OS percentage catches up. This is a calibration gap, not a faulty battery. Do one full drain to auto-shutdown, then charge to 100% without fast charging — the coulomb counter resets and the shutdowns stop.
Fast charging isn't working on the first cycle after I put in the replacement cell — is something wrong?
On the first charge cycle with a new cell, the G740's charge IC sometimes won't negotiate the fast charge protocol until it has completed one standard charge pass. The BMS on a fresh cell presents a slightly different impedance signature, and the USB-PD or proprietary handshake can fall back to standard 5V charging as a precaution. This is normal behaviour. Let the first cycle complete at standard charge rate, then fast charging should activate on the second cycle once the BMS and charge IC have exchanged a full handshake.
The phone feels warm near the battery while charging with the new cell — should I be concerned?
A new Li-ion cell has higher internal impedance than a worn-in cell, so the charge IC pushes more voltage across that resistance during the constant-current phase, generating more heat than you'd see with an aged cell. This is most noticeable in the first two or three charge cycles and reduces as the cell's impedance settles. If the phone is charging at room temperature and the warmth eases after the first few cycles, no action is needed. If it stays hot or the case becomes uncomfortable to hold after three cycles, check that the charge port is fully seated and that no fast charge accessory is forcing current above the G740's rated input.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Related Products
Engineered for Performance. Built to Last.
Check out our top-rated selection of reliable products built to last. We offer high-quality options that deliver consistent performance for all your needs.