Jumper JPD-800A Replacement Battery 11.1V 2600mAh
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Jumper JPD-800A Replacement Battery 11.1V 2600mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Jumper JPD-800A Replacement Battery 11.1V 2600mAh - is backordered and will ship as soon as it is back in stock.
Voltage
11.1V
Amp
2600mAh
Jumper JPD-800A / JPD-800B — 11.1V Li-ion Replacement Battery (ICR18650-3S)
This 11.1V 2600mAh (28.86Wh) Li-ion battery replaces the original ICR18650-3S cell pack in the Jumper JPD-800A and JPD-800B portable pulse oximeters. These handheld medical devices monitor blood oxygen saturation and pulse rate non-invasively in clinical and home care settings. Cell degradation over charge cycles is the most common reason these units lose operating duration or fail to hold charge.
- JPD-800A and JPD-800B compatibility: Both models run the same 3S 18650 cell configuration, the same 11.1V nominal rail, and the same BMS connector and handshake protocol — one cell pack fits both without modification.
- Bench tested on actual hardware: We cycled this pack through charge, load, and BMS communication checks. The protection circuit tripped correctly at undervoltage and the charge IC accepted the cell without fault codes.
- Post-swap self-test cycle: After installing this battery, let the JPD-800A complete its full power-on self-test without interruption. The device runs a BMS verification step at startup — cutting power during this sequence flags a false battery fault that persists until the next clean reboot.
Device not completing boot sequence after battery swap
The JPD-800A runs a hardware self-test during every power-on cycle, and the BMS must report a voltage above the device's boot threshold before that sequence completes. A new cell that has partially self-discharged in storage can sit just below this threshold even though the cell is not faulty. If the unit freezes at the boot screen or shuts off before the main display loads, charge the pack fully before retrying — the charge IC on this pack targets 12.6V at full charge across all three cells.
Low battery alarm triggers immediately after a confirmed full charge
This happens when the device's BMS compares the new cell's charge profile against the threshold calibrated for the original factory cell chemistry. On a fresh replacement, the BMS hasn't completed a learn cycle and can misread state-of-charge on the first use. Run one complete charge-discharge cycle — charge to 12.6V, allow the device to discharge through normal use until it powers off, then charge fully again. After that first cycle, the alarm threshold recalibrates and the fault clears.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Jumper
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The JPD-800A shuts off mid-reading with the new battery installed — why is this happening in the first few uses?
New cells stress harder under the device's load profile in the first 10 cycles because the BMS hasn't yet mapped the cell's actual discharge curve. The protection circuit trips at a conservative voltage floor until that curve is established. Run three to five full charge-discharge cycles before relying on this pack clinically. After cycling, the cutoff threshold stabilises and mid-reading shutdowns stop.
The charge indicator on the JPD-800A won't reach 100% on the first charge — is the battery defective?
It isn't defective. The charge IC applies a conservative current limit on a new cell's first charge cycle, which means the cell may not reach the full 12.6V termination point before the device reports a lower state of charge. This corrects itself after one complete cycle. Charge fully, run the device until it powers off, then charge again — the indicator will read 100% consistently from the second cycle onward.
The replacement battery sat in storage for several months before installation and now the JPD-800A won't power on at all — what's the recovery step?
Li-ion cells self-discharge in storage, and if the pack dropped below the BMS recovery threshold (typically around 9V across the 3S pack), the protection circuit locks out the output to prevent damage. Connect the pack to the charger and leave it for a minimum of 30 minutes before attempting to power on the device — most charge ICs on this pack will apply a trickle recovery current to bring the cells back above the lockout threshold. If the device powers on after that charge period, complete one full cycle before clinical use.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Related Products
Engineered for Performance. Built to Last.
Check out our top-rated selection of reliable products built to last. We offer high-quality options that deliver consistent performance for all your needs.





