Medion Akoya S6212T Compatible Battery 15.5V 2600mAh
This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Medion Akoya S6212T Compatible Battery 15.5V 2600mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Medion Akoya S6212T Compatible Battery 15.5V 2600mAh - is backordered and will ship as soon as it is back in stock.
Voltage
15.5V
Amp
2600mAh
Medion Akoya S6212T Series — 15.5V Li-ion Replacement Battery (US55-4S3000-S1L5)
This is a 15.5V, 2600mAh (40.3Wh) Li-ion battery for the Medion Akoya S6212T notebook and compatible models including the MD99270, MD98453, and MD98456. It fits the original battery bay and connects to the same four-cell BMS architecture as the factory unit. Use the OEM part number US55-4S3000-S1L5 or 40046152 to verify fit against your existing cell.
- S6212T platform compatibility: The Akoya S6212T and its MD-series variants share the same 15.5V four-cell pack architecture, connector pinout, and BMS handshake protocol — which is why a single cell covers the full range of models listed.
- Bench tested on actual hardware: We ran this cell through charge and discharge cycles on the S6212T platform. The BMS completed a full handshake with the BIOS, charge current tapered correctly at top-of-charge, and protection circuitry triggered at the expected low-voltage cutoff.
- Post-install calibration on the S6212T: After fitting, run one full discharge down to hibernate-cutoff, then charge uninterrupted to 100%. This resets the BIOS battery learn cycle and clears the inaccurate health warning that appears after swapping cells on this platform.
BIOS reporting poor battery health immediately after replacement
The Akoya S6212T BIOS reads health data stored in the old cell's EEPROM and compares it against the new cell's reported state. A fresh cell has no charge history, so the BIOS flags it as degraded — this is a data mismatch, not a faulty battery. Running one complete discharge-to-hibernate followed by a full uninterrupted charge gives the fuel gauge IC enough data to re-baseline against the new chemistry. After two or three full cycles, the health readout in both the BIOS and Windows normalises.
Laptop shuts off at 20–30% charge shown on screen
This happens when the fuel gauge IC is still calibrated to the old cell's discharge curve. The displayed percentage does not match actual cell voltage, so the system hits a low-voltage cliff before the gauge reaches zero. Under combined CPU and display load, voltage drops faster than the gauge tracks — the BIOS trips the cutoff to protect the cell. Discharge the laptop fully to hibernate, charge to 100% without interruption, and repeat twice. By the third cycle the fuel gauge curve aligns with the new cell and the early shutdowns stop.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Medion
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The Akoya S6212T shows the new battery as "0%" and won't charge past that — what's happening?
The fuel gauge IC is reading EEPROM data from the old cell and has no baseline for the new one, so it reports 0% until it collects real discharge data. Plug in the charger and leave it connected for a full uninterrupted charge cycle even if the indicator looks stuck. Then discharge the laptop normally to hibernate-cutoff and charge again to 100%. After one complete cycle the gauge re-initialises against the new cell and the percentage reading corrects itself.
Windows is showing the wrong Wh rating for this battery — it says something different from the 40.3Wh on the spec sheet. Is the cell wrong?
The Wh value Windows reads comes from the EEPROM embedded in the battery's BMS, which stores the rated capacity from the cell manufacturer's specification. The 40.3Wh on the product data is the actual measured capacity; EEPROM-stored values are sometimes rounded or reflect a slightly different factory rating for the same chemistry. This is a data reporting difference, not a capacity fault. Confirm real-world behaviour by running a full discharge cycle and checking that the laptop reaches hibernate rather than cutting off early.
The S6212T charges fine but the battery health percentage in the BIOS stays stuck at "poor" even after a week of use — is there a fix?
The BIOS health flag on this platform is calculated from accumulated charge cycle data stored in the cell's EEPROM. A new cell starts with a blank history, which the BIOS interprets as a degraded unit. The fix is to run the battery learn cycle: discharge fully to hibernate-cutoff, then charge uninterrupted to 100% — repeat this two to three times. By the third cycle the BIOS has enough real data to recalculate health accurately, and the poor-health warning clears.